Hardware features
1
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you run the
chassis with an uncovered slot, the system may overheat.
Figure 1
,
Figure 2
,
Figure 3
, and
Figure 4
show the BigIron RX Series chassis and the slots into
which you install the various modules. You must install the primary power supplies and the
redundant power supplies as described in the figures.
Figure 1
,
Figure 2
,
Figure 3
, and
Figure 4
also show an electrostatic discharge (ESD) connector,
into which you can plug an ESD wrist strap to ground yourself while handling and installing
modules.
DANGER
For safety reasons, the ESD wrist strap should contain a 1 meg ohm series resistor.
The BigIron RX-16 and BigIron RX-32 chassis versions also include a grounding lug connector,
located on the rear panel (left side). The BigIron RX-4 and BigIron RX-8 have two threaded holes on
the right side of the chassis to accommodate the addition of a ground lug connector.
Management modules
The management module controls the BigIron RX Series hardware components, runs the
networking protocols, and provides the Real Time Operating System (RTOS).
Each BigIron RX Series chassis requires one management module and can accept a second one for
redundancy. A redundant management module works along with the active management module.
If the active module becomes unavailable, the redundant management module automatically
takes over the system operation, minimizing system downtime.
You can install management modules in dedicated slots marked M1 and M2. By default, the
system considers the module installed in the slot marked M1 to be the active management
module.
The BigIron RX-32 chassis uses a different management module than any of the other Brocade
products. You cannot use management modules designed for the BigIron RX-32 in any of the other
BigIron RX Series chassis or management modules designed for the BigIron RX-4, BigIron RX-8 or
BigIron RX-16 in the BigIron RX-32 chassis.
NOTE
The BigIron RX Series management module is dedicated, which means that you must install it in the
BigIron RX Series chassis only. If you attempt to install the BigIron RX Series management module
in another Brocade chassis or a management module intended for another Brocade chassis in the
BigIron RX Series chassis, the chassis and module will not function properly.
Additionally, the BigIron RX-32 chassis uses a different management module than any of the other
BigIron RX Series chassis. You cannot use management modules designed for the BigIron RX-32 in
any of the other Brocade device, because it will not function properly.
A management module is hot swappable, which allows you to remove and replace it without
powering down the system.
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...