84
BigIron RX Installation Guide
53-1001811-01
Verifying proper operation
2
DC OK
Green (steady)
The power supply is
providing DC power to
the BigIron RX Series
chassis.
Off
The power supply is not supplying
power to the chassis. If the AC OK
LED is lit Green, then there is a
problem with the power supply
and it must be replaced.
ALM
ALM
The power supply is in
normal operating
condition.
Amber
The power supply is
malfunctioning.
Power supplies DC
DC IN
Green (steady)
The power supply is
receiving DC power
from a DC power
source.
Off
The power supply is not receiving
power from a DC power source You
can do the following:
•
Make sure that the power
supply cables are connected
securely to the power source
and the power supply.
•
Make sure that the DC power
source is 48 VDC @ 30 A
(Operating voltage range is
40-60VDC).
•
Make sure that the power
source has power.
DC OUT
Green (steady)
The power supply is
providing DC power to
the BigIron RX Series
chassis.
Off
The power supply is not supplying
power to the chassis. If the DC IN
LED is lit Green, then there is a
problem with the power supply
and it must be replaced.
ALM
Off
The power supply is in
normal operating
condition.
Amber
The power supply is
malfunctioning.
TABLE 13
Desired and abnormal LED states after system power on (Continued)
LED
Desired state
Meaning
Abnormal
state
Meaning or action
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...