164
BigIron RX Installation Guide
53-1001811-01
Software images required
7
This section describes each of the software images required to operate a BigIron RX Series switch
as described in
Table 24
. Also,
Figure 87
illustrates how each of the files are stored on the
management and interface modules.
FIGURE 87
Management and interface modules flash images
The software images are described in the following:
IronWare image
An IronWare image, also known as the
software image
, contains the application software, the
network protocols and features that define the characteristics of the device. IronWare images can
be loaded in the Primary or Secondary location of Code Flash on the modules. IronWare images are
named as described in
Table 24
. There is one IronWare image for the management module and
another for the interface module.
NOTE
The IronWare image for interface modules is loaded on both the interface and managment modules.
The reason for this redundancy is to verify that the same image is loaded on all the interface
modules. The management module does not run the interface module code, it only compares the
code with the code on the other interface modules. If the code is not the same, the files are
synchronized and updated to match the interface code on the management module.
Monitor image
A Monitor image, also known as the
real time operating system
, allows hardware to run multiple,
parallel, distributed functions. The Monitor Image delegates low-level functions to the smaller
processor on each interface module. Monitor images are loaded in the Code Flash and Boot Flash
on the interface and management modules. Monitor images are named as described in
Table 24
.
Boot image
The Boot image, which is packaged with the Monitor image, contains initialization instructions for
the hardware startup. Boot images are named as described in
Table 24
.
Code Flash
Primary Ironware Image:
rmpr
<xxxxx>
rIp
<xxxxx>
Secondary Ironware Image:
rmpr
<xxxxx>
rIp
<xxxxx>
Boot Image:
rmb
<xxxxx>
rIb
<xxxxx>
FPGA Image:
mbridge
Boot Flash
Monitor Image:
rmb
<xxxxx>
rIb
<xxxxx>
Management Module
Flash Memory
Interface Module
Flash Memory
Code Flash
Primary Ironware Image:
rIp
<xxxxx>
Secondary Ironware Image:
rIp
<xxxxx>
Boot Image:
rIb
<xxxxx>
Boot Flash
Monitor Image:
rIb
<xxxxx>
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...