background image

KNX Multi Functional Switch 

 

 

 

 

Version: 1.0 

               Jan-20 

  Page 1/20 

 

 

KNX Multi Functional Switch 

 

Reference Manual 

 

 

 

 

 

 

 

V1.0 

 

 

 

KNX Multi Functional Switch MS104 FA 

 

WRKT62045FA 

KNX Multi Functional Switch MS104-D FA   

WRKT62145FA

 

Summary of Contents for MS104 FA

Page 1: ...X Multi Functional Switch Version 1 0 Jan 20 Page 1 20 KNX Multi Functional Switch Reference Manual V1 0 KNX Multi Functional Switch MS104 FA WRKT62045FA KNX Multi Functional Switch MS104 D FA WRKT62145FA ...

Page 2: ...ument updates 4 3 2 List of abbreviations 4 4 Product description 5 4 1 General information 5 4 2 Main features 5 4 3 Technical information 6 4 4 Product versions 6 5 Product parts 7 6 Main screen 8 7 Display menus 11 7 1 User settings menu 11 7 2 Advance settings menu 13 7 3 Weekly program settings menu 17 7 4 Thermostat off 20 ...

Page 3: ...KNX Multi Functional Switch Version 1 0 Jan 20 Page 3 20 2 List of figure Figure 1 Product front view 7 ...

Page 4: ... Switch Version 1 0 Jan 20 Page 4 20 3 Document overview 3 1 Document updates Version Date Modifications 1 0 December 2019 Preparation of the final version Table 1 3 2 List of abbreviations Abbreviation Description Table 2 ...

Page 5: ...ed values to other KNX devices on the bus line KNX Multi Functional Switch can be installed in flushed mounted or hollow wall boxes 4 2 Main features Configurable touch buttons up to 4 Gang for single or rocker operation Sound feedback for touch buttons functions Configurable feedback LEDs can be used with buttons or KNX group objects Customized icon label stickers for touch buttons Activating sta...

Page 6: ... EN60529 Safety class III to IEC 60664 1 Cable length for external inputs Maximum 3 m Temperature measurement 0 C to 45 C Relative humidity 0 to 100 Table 3 4 4 Product versions Product Features WRKT62045FA WRKT62145FA KNX Multi Functional Switch 4 Gang MS104 FA KNX Multi Functional Switch 4 Gang MS104 D FA Button Functions Thermostat Functions Scene Actuator LCD Display Table 4 ...

Page 7: ...ional Switch Version 1 0 Jan 20 Page 7 20 5 Product parts Thermostat buttons Figure 1 Product front view Feedback LED Icon LED Up OK Down Touch button surface Gang B Gang D Gang C Gang A Thermostat Buttons and Display ...

Page 8: ...on Name Touch type Current menu Target menu Up Short Main screen User settings menu OK Short Main screen User settings menu Down Short Main screen User settings menu Up Long Main screen Advance settings menu OK Long Main screen Thermostat off Down Long Main screen Weekly settings menu Table 5 The following table includes some basic information which are shown at main screen For more information ab...

Page 9: ...l External temperature input value Internal humidity sensor value External humidity value Current thermostat operation mode Current thermostat control mode Current thermostat control mode is active Current thermostat fan level and fan mode Thermostat weekly program is active ...

Page 10: ...KNX Multi Functional Switch Version 1 0 Jan 20 Page 10 20 Information Visual Day of week Table 6 ...

Page 11: ...screen Setpoint temperature Table 7 Icon Name Touch type Current setting Target setting OK Short Main screen Thermostat operation mode OK Short Operation mode Fan level OK Short Fan level Swing level OK Short Swing level Main screen Table 8 Settings Visual Setpoint temperature If there is not a restriction for manual control at the system Up Down buttons increase or decrease the setpoint within sp...

Page 12: ...al control at the system Up Down buttons increase or decreasethe fan level within specific limit No operation for 10 seconds saves the value and returns to main screen OK button saves the value and goes to the next setting Swing level The flap icon flashes If level is selected as Auto the flap icon appears at the main screen If there is not a restricted for manual control at the system Up Down but...

Page 13: ...screen Clock Up Short Clock Day of week OK Short Day of week Hour OK Short Hour Minute OK Short Minute Sound level OK Short Clock Sound level OK Short Sound level Display brightness level OK Short Display brightness level Icon LEDs brightness level OK Short Icon LEDs brightness level Feedback LEDs brightness level OK Short Feedback LEDs brightness level Thermostat control mode OK Short Thermostat ...

Page 14: ...Clock Hour The clock icon and hour digit flashes Up Down buttons increase or decreasehour No operation for 10 seconds does not save the value and returns to main screen OK button does not save the value and goes to the next setting Clock Minute The clock icon and minute digit flashes Up Down buttons increase or decreaseminute No operation for 10 seconds does not save the value and returns to main ...

Page 15: ... flashes Up Down buttons increase or decreasethe icon LEDs brightness level within 0 low limit specific high limit No operation for 10 seconds saves the value and returns to main screen OK button saves the value and goes to the next setting Feedback LEDs brightness level The lamp icon flashes Feedback LEDs must be turned on to see the effect of the change Up Down buttons increase or decreasethe fe...

Page 16: ...0 Jan 20 Page 16 20 Settings Visual Thermostat control mode Up Down buttons changes thermostat control mod No operation for 10 seconds saves the value and returns to main screen OK button saves the value and returns to main screen Table 11 ...

Page 17: ...tatus Down Long Weekly program status Select program day OK Short Select program day Select mode OK Short Select mode Select hour OK Short Select hour Select minute Table 12 Settings Visual Weekly program status The calendar and days of week icons flash Up Down buttons changes weekly program status If On is selected weekly program is enabled No operation for 10 seconds saves the value and returns ...

Page 18: ... No operation for 10 seconds returns to main screen If the operatin mode is selected as none OK button changes the zone number If the operation mode is not selected as none OK button goes to the next setting Long touch at the Down button saves the values and changes setting to select program day Select hour The zone number icon and hour digits flash Up Down buttons changes hour for the operation m...

Page 19: ...umber icon and minute digits flash Up Down buttons changes minute for the operation mode No operation for 10 seconds returns to main screen OK button changes setting to the select mode for the next zone Long touch at the Down button saves the values and changes setting to select program day Table 13 ...

Page 20: ...Thermostat off Settings Visual Thermostat off Up Down buttons increase or decreasethe setpoint within specific step and limit Long touch to OK button changes thermostat status On If clock is activated for main screen it is shown on the thermostat off mode Table 14 ...