Specifying an immediate boot from the management module’s PCMCIA slots
For example, to specify an immediate boot for the interface module installed in slot 1 from the
management module’s PCMCIA slot 1, enter the following command at the Privileged EXEC level of
the CLI:
BigIron RX# lp boot system slot1 primary 1
Syntax: lp boot system slot1 | slot2 <filename> <slot-number>
The slot1 and slot2 keywords indicate the management module’s PCMCIA slot from which to boot
the interface module.
The <filename> parameter specifies the name of the image from which to boot the interface
module.
The <slot-number> parameter specifies the BigIron RX chassis slot number that contains the
interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1 – 8
for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from the management module’s flash memory
For example, to specify an immediate boot from the primary IronWare image in the management
module’s flash memory for the interface module installed in slot 1, enter the following command at
the Privileged EXEC level of the CLI:
BigIron RX# lp boot system mp primary 1
Syntax: lp boot system mp primary | secondary <slot-number>
The primary and secondary keywords specify the primary or secondary IronWare image in the
management module’s flash memory.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from the interface module’s flash memory
For example, to specify an immediate boot from the primary IronWare image in the interface
module’s flash memory for the interface module installed in slot 1, enter the following command at
the Privileged EXEC level of the CLI:
BigIron RX# lp boot system flash primary 1
Syntax: lp boot system flash primary | secondary <slot-number>
The primary and secondary keywords specify the primary or secondary IronWare image in the
interface module’s flash memory.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from a TFTP server
For example, to specify an immediate boot for the interface module installed in slot 1 from a TFTP
server, enter the following command at the Privileged EXEC level of the CLI:
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...