BigIron RX Installation Guide
53-1001811-01
Managing the cooling system
5
low – The system sets the fan speed to low.
med – The system sets the fan speed to medium.
med-high – The system sets the fan speed to medium-high.
Monitoring the cooling system
You can monitor the following aspects of the BigIron RX Series cooling system:
•
The temperature of the fan control modules
•
The status and speed of the fans
•
The temperature warnings sent to the system log and that generate an SNMP trap
Displaying fan tray status and speed
The CLI provides two commands that allow you to display the status and speed of the four-speed
fans in the BigIron RX Series chassis. To display this information, you can enter the following
command at any level of the CLI:
Syntax: show chassis
For information about all output generated by the show chassis command,refer to
“Displaying
chassis status and temperature readings”
on page 113.
Displaying temperature warnings
If the temperature of a module exceeds the high temperature threshold for any of the fan speeds,
the system sends a warning message to the system log and an SNMP trap. (For more information
about the low and high temperature thresholds, refer to
“Changing temperature thresholds for
modules and fan speeds”
on page 117.) This section describes how to view the system log. If you
have configured the BigIron RX Series system to use a Syslog server or SNMP trap receiver, refer to
the documentation for the server or receiver.
TABLE 22
Fan status and speed fields
This field...
Displays...
Status
The status can be one of the following:
•
OK – The fan is functioning properly and is keeping the temperature of each module within
an acceptable temperature range.
•
Failed – The fan is not functioning properly or the fan control module cannot control the
fan.
Speed
The speed can be one of the following:
•
LOW – The fan is functioning at 50 percent of capacity
•
MEDIUM – The fan is functioning at 75 percent of capacity
•
MEDIUM-HIGH – The fan is functioning at 90 percent of capacity
•
HIGH – The fan is functioning at 100 percent of capacity
BigIron RX# show chassis
...
--- FANS ---
Right Fan Tray: Fan 5: Status = OK, Speed = LOW (50%) (RPM 3333)
Right Fan Tray: Fan 6: Status = OK, Speed = LOW (50%) (RPM 3488)...
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...