82
BigIron RX Installation Guide
53-1001811-01
Verifying proper operation
2
Interface module
Pwr
On
The module is
receiving power.
Off
The module is not receiving power.
You can do the following:
•
Make certain that the
module is installed properly.
For more information, refer to
“Installing BigIron RX-4
modules”
on page 33,
“Installing BigIron RX-8
modules”
on page 42,
“Installing BigIron RX-16
modules”
on page 52, or
“Installing BigIron RX-32
modules”
on page 62.
•
The module may not be
receiving enough power.
Brocade recommends
installing power supplies in a
fully redundant configuration
as described in
“Installing
power supplies in a BigIron
RX-4 chassis”
on page 35,
“Installing power supplies in
the BigIron RX-8 chassis”
on
page 44,
“Installing power
supplies in a BigIron RX-16
chassis”
on page 54, or
“Installing power supplies in
a BigIron RX-32 chassis”
on
page 75.
•
Check the Pwr LED on the
management module. If it is
on, this module may be
holding the power from the
interface module.
•
Enter the show chassis
command at any level of the
CLI to determine if the
management module
recognizes the presence of
all power sources.
•
If using AC power supplies,
see the entry for the AC
power supply LED in this
table for more information.
Mgmt Act
During
initialization:
steady blinking.
After initialization:
occasional
blinking.
The active
management
module’s processor
and the interface
module’s processor
are communicating.
Off for an
extended
period.
The interface module may be in
interactive mode. Check the
status of the module by entering
the show module command at any
CLI prompt.
TABLE 13
Desired and abnormal LED states after system power on (Continued)
LED
Desired state
Meaning
Abnormal
state
Meaning or action
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...