BigIron RX Installation Guide
51
53-1001811-01
Installing a BigIron RX-16 switch
2
FIGURE 34
Mounting the BigIron RX-16 or BigIron RX-32 chassis in a rack
4. Slide the chassis down so that the screw heads are in the narrow portion of the keyhole slots.
5. Tighten the screws to secure the chassis in place.
NOTE
To provide better grounding of the chassis to the rack, attach the chassis to the rack using star
washers. Additionally, if any single hole grounding lugs are used star washers shall be used as a
means to prevent rotation of the lug.
6. Repeat
step 2
through
step 5
to mount each subsequent chassis in the same rack.
Removing the slot blanks
The BigIron RX-16 chassis ships with slot blanks installed in all module slots. The slot blank covers
a slot that does not currently have a module installed in it, ensuring proper airflow within the
chassis. If you plan to install a module in a particular slot, you must remove the slot blank.
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you run the
chassis with an uncovered slot, the system may overheat. Tighten the screws that secure the slot
blanks so that they remain in place when removing adjacent panels or modules.
Although the slot blanks are different in size, the procedure for removing them from the BigIron RX
Series chassis is the same. Therefore, this section provides one procedure that applies to all slot
blanks.
You will need a flat-head screwdriver to perform this task.
Follow the steps given below to remove a slot blank.
1. Loosen the screws on either end of the slot blank by hand or with a flat-head screwdriver.
2. Pull the slot blank out of the chassis, and store it in a safe place for future use.
Summary of Contents for BigIron RX-16
Page 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Page 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Page 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Page 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Page 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Page 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...