Troubleshooting by Indication on the Remote Controller
ESIE09-08
158
Troubleshooting
∗
1: Coil check method for the moving part of the electronic expansion valve
Disconnect the electronic expansion valve from the PC board and check the continuity between
the connector pins.
(Normal)
{
: Continuity
×: No continuity
(V3067)
(Orange) 1
(Red) 2
(Yellow) 3
(Black) 4
( Gray) 5
(White) 6
Pin No.
1. Orange
2. Red
3. Yellow
4. Black
5. Gray
6. White
1. Orange
×
{
Approx.
100
Ω
×
{
Approx. 50
Ω
×
2. Red
×
{
Approx.
100
Ω
×
{
Approx. 50
Ω
3. Yellow
×
{
Approx. 50
Ω
×
4. Black
×
{
Approx. 50
Ω
5. Gray
×
6. White