ESIE09-08
Field Setting
Test Operation
85
C
Leaving water temperature limits
00
Set point: leaving water maximum
temperature
80
37~80
1
°C
01
Set point: leaving water minimum
temperature
25
25~37
1
°C
02
Not applicable. Do not change the default
value.
20
18~22
1
°C
03
Not applicable. Do not change the default
value.
5
5~18
1
°C
D
Domestic water heating retention times
00
Set point: minimum time for domestic water
heating
10
5~20
1
—
01
Set point: maximum time for domestic water
heating
30
10~60
5
—
02
Set point: interval minimum stop time of
domestic water heating
15
5~30
5
—
E
Service mode
00
Vacuum mode
0
0/1
—
—
01
Not applicable. Do not change the default
value.
0
(OFF)
0/1
—
—
02
Not applicable. Do not change the default
value.
0
(OFF)
0/1
—
—
03
Not applicable. Do not change the default
value.
1
0~2
1
—
04
Pump only operation
0
0~2
1
—
First
code
Second
code
Setting name
Installer setting at variance with
default value
Default
value
Range
Step
Unit
Date
Value
Date
Value
Summary of Contents for ERSQ 011AAV1
Page 2: ......
Page 12: ...Introduction ESIE09 08 x...
Page 16: ...Model Names of Indoor Outdoor Units Tanks ESIE09 08 4 General Information...
Page 22: ...Specifications ESIE09 08 10 Specifications...
Page 38: ...Functional Parts Layout ESIE09 08 26 Refrigerant Circuit...
Page 248: ...Method of Replacing the Inverter s Power Transistors Modules ESIE09 08 236 Appendix...