Troubleshooting by Indication on the Remote Controller
ESIE09-08
132
Troubleshooting
3.3
“A9”
Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (K1E) R-410A circuit
Remote Control
Display
A9
Subcode 0
Applicable
Models
All indoor and outdoor unit models
Method of
Malfunction
Detection
Malfunction
Decision
Conditions
Supposed
Causes
Malfunction of moving part of electronic expansion valve
Defect of indoor unit PC board (A1P)
Defect of connecting cable, bad wire
Troubleshooting
(V2781)
Caution
Be sure to turn off power switch before connect or disconnect connector, or
parts damage may be occurred.
After connecting, turn the power
supply off and then back on.
X7A [1, 2, 3, 4, 5, 6]
Replace the moving part of the
electronic expansion valve.
YES
YES
NO
NO
Replace the connecting cable.
If you turn the power supply off and
turn on again, and it still does not
help, replace the indoor unit PC
board (A1P).
NO
YES
The
electronic
expansion valve is
connected to X7A of the
indoor unit PC
board.
Normal
when coil
check (
*
1) of the
moving part of the electronic
expansion valve is
checked.
The connecting
cable is short-circuited or
disconnected.
Summary of Contents for ERSQ 011AAV1
Page 2: ......
Page 12: ...Introduction ESIE09 08 x...
Page 16: ...Model Names of Indoor Outdoor Units Tanks ESIE09 08 4 General Information...
Page 22: ...Specifications ESIE09 08 10 Specifications...
Page 38: ...Functional Parts Layout ESIE09 08 26 Refrigerant Circuit...
Page 248: ...Method of Replacing the Inverter s Power Transistors Modules ESIE09 08 236 Appendix...