ESIE09-08
PCB Layout for EKHBRD 011/014/016 AAV1
Refrigerant Circuit
43
Legend
Connector
Color
Connected to - function
L12A
-
Reactor - phase 1
L22A
-
Reactor - phase 2
L32A
-
Reactor - phase 3
U
-
Compressor - phase U
V
-
Compressor - phase V
W
-
Compressor - phase W
X32A
White
HPS
X104A
Ivory
Control PCB X4A
X105A
White
Control PCB X5A
X106A
Red
Fan motor M1F
X107A
Ivory
Fan motor M2F
X108A
White
Control PCB X8A
X109A
Orange
Control PCB X9A
X111A
White
Fin thermistor
X141A
White
-
X142A
White
-
X191A
Blue
Fan reactor
T1
-
Test pin DC+
T2
-
Test pin DC-