![background image](http://html.mh-extra.com/html/daikin/2amx40g2v1b/2amx40g2v1b_service-manual_501057077.webp)
SiBE12-933_A
Main Functions
Function and Control
67
1.10 ECONO Mode
Outline
F(A)TXS20-50G, ATX20-35G, FVXS25-50F
ECONO Mode is a function that sets a limit for power consumption. A maximum power
consumption of 1000 W (40 class) or 1300W (50 class) is the limit for the 2MK(X)S40/50H and
2AMX40/50G. This mode is useful for preventing circuit breakers from being overloaded by the
use of multiple air conditioners and other electrical devices. The function is easily activated from
the remote controller by pushing the ECONO button. ECONO Mode is available for all wall-
mounted models.
Details
ECONO mode can be activated while the unit is running. The remote controller can send the
ECONO command when the unit is in COOL, HEAT, DRY, or AUTO operation.
When the ECONO command is valid, the input current is under reducing control.
Also, the upper limit of frequency is restricted.
(R8461)
Power consumption
Normal
operation
Maximum during
normal operation
40 class : 1000 W
50 class : 1300 W
Econo
Mode
Maximum during
Econo Mode
Time
From start up until set
temperature is reached
This diagram is a representation for illustrative purposes only.
Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.