![background image](http://html.mh-extra.com/html/daikin/2amx40g2v1b/2amx40g2v1b_service-manual_501057079.webp)
SiBE12-933_A
Main Functions
Function and Control
69
2. The motions in energy saving operation (for example: in cooling)
When a microcomputer does not have a signal from the sensor in 20 minutes, it judges that
nobody is in the room and operates the unit in temperature shifted 2°C from the set
temperature. (Cooling/Dry : 2°C higher, Heating : 2°C lower and AUTO : according to the
operation mode at that time.)
★
1 In case of FAN mode, the fan speed reduces by 60 rpm.
3. Airflow direction in 2 AREA INTELLIGENT EYE operation
Detection method: The opposite area of detected area is set as the target direction.
1. Detection signal ON in both area A and B: Shift the airflow direction to area B (left side)
2. Detection signal ON in area A: Shift the airflow direction to area B (left side)
3. Detection signal ON in area B: Shift the airflow direction to area A (right side)
4. Detection signal OFF in both area A and B: No change
* When the detection signal OFF in both area A and B, the unit starts energy saving operation.
Others
The dry operation can not command the setting temperature with a remote controller, but
internally the set temperature is shifted by 1°C.
(R8350)
within 20
minutes.
20 min.
ON
OFF
Human detection
signal
(From area A or B)
20 min.
RESET.
Cooling : Set temp. + 2°C
Heating : Set temp. – 2°C
Set temp.
INTELLIGENT EYE
LED
ON
OFF
Remote controller
INTELLIGENT EYE
button
ON
OFF
Operation
ON
OFF
Fan speed (
1)
OFF
Set speed
Set speed – 60 rpm
Set speed
(R3853)
Wall
Top view
Indoor unit
Area B
Area A
Right
Left
Human