![background image](http://html.mh-extra.com/html/daikin/2amx40g2v1b/2amx40g2v1b_service-manual_501057270.webp)
Field Settings
SiBE12-933_A
260
Trial Operation and Field Settings
4.2.2 How to Change the Field Settings with the Wireless Remote
Controller
Optional
accessories
If optional accessories are mounted on the indoor unit, the indoor unit setting may have to be
changed.
Refer to OH06-1 or the installation manual (optional handbook) for each optional accessory.
Wireless remote
controller
BRC7E531W7(C/O), BRC7E530W7(H/P)
To set the field settings, you have to change:
“Mode No.”
“First code No.”
“Second code No.”.
To change the field settings, proceed as follows:
Step
Action
1
Press the [Inspection / Test] button for 4 seconds during normal mode to enter the
field setting mode.
2
Press the MODE button to select the desired “Mode No.”.
3
Press the UP button to select the “First code No.”.
4
Press the DOWN button to select the “Second code No.”
5
Press the Reserve button to confirm the setting.
6
Press the [Inspection / Test] button to return to the normal mode.
RESERVE button
[Inspection / Test] button
Mode No.
Field setting mode
UP button
DOWN button
First code No.
Second code No.
MODE button
(R11737)