Removal Procedure
245
1.7
Removal of the Compressor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
Be careful so as not to burn
the compressor terminals or
the name plate.
2
Disconnect the flag-
shaped terminals.
3
Detach the terminals by
long nose pliers.
Release the hooks by a
flat screwdriver to
remove the overload
protector.
4
Detach the overload
protector.
(R7637)
Terminal cover
(R7638)
Protection bushing
for lead wires
Red (U)
Blue (W)
Yellow (V)
(R7639)
(R7640)