2.1.5 Ceiling Mounted Cassette Type
FFQ25B8V1B, FFQ35B8V1B, FFQ50B8V1B
3D038357B
: CONNECTER DISCRIMINATION COLOUR FOR COMPONENTS.
: CONNECTER COLOUR FOR COMPONENTS.
: CONNECTER COLOUR FOR PRINTED CIRCUIT BOARD.
IN CASE OF SIMULTANEOUS
OPERATION SYSTEM
INDOOR UNIT
(MASTER)
INDOOR UNIT
(SLAVE)
T
O
OUT
D
OO
R
U
N
IT
X2M
X2M
1
2
3
1
2
3
REMOTE
CONTROLLER
TO OUTDOOR
UNIT
X2M
1
2
3
H05VV-U4G2.5
BLK
WHT
RED
GRN/YLW
F1U
X27A
A1P
A3P
A4P
NOTE)3
X24A
X2A
X1A
X1A
SS1
SS2
H1P
H2P
H3P
H4P
BS1
RECEIVER/DISPLAY UNIT
X40A
RC
TC
X60A
X61A
X19A
X18A
X17A
R1T
R2T
t°
t°
R3T
t°
YLW
WHT
YLW
X10A
KPR
X25A
T1R
t°
X11A
YLW
YLW
M
~
M1P
X33A
X35A
HAP
X36A
X15A
V1TR
X20A
X5A
A1P
X24A
NOTE)3
GRN
NOTE)5
NE
WIRED
REMOTE
CONTROLLER
F2
F1
P2
P1
X1M
SS1
P2
P1
R1T
C1
YL
W
WH
T
RED
BLK
M1F
Q1M
M
~
MSW
M1S
S1L
C1
T1R
X2M
A1P
X1M
CONTROL BOX
NOTES)
1.
: TERMINAL
: FIELD WIRING
2. IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT
IN ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.
3. X24A IS CONNECTED WHEN THE WIRELESS REMOTE CONTROLLER KIT IS
BEING USED.
: CONNECTOR
A1P
PRINTED CIRCUIT BOARD BS1
PUSH BUTTON(ON/OFF)
C1
CAPACITOR(M1F)
H1P
LIGHT EMITTING DIODE
(ON-RED)
F1U
FUSE(F5A 250V)
HAP
LIGHT EMITTING DIODE
(SERVICE MONITOR GREEN)
H2P
LIGHT EMITTING DIODE
(TIMER-GREEN)
KPR
MAGNETIC RELAY(M1P) H3P
LIGHT EMITTING DIODE
(FILTER SIGN-RED)
M1F
MOTOR(INDOOR FAN)
M1P
MOTOR(DRAIN PUMP)
H4P
LIGHT EMITTING DIODE
(DEFROST-ORANGE)
M1S
MOTOR(SWING FLAP)
Q1M
THERMO SWITCH(M1F EMBEDDED)
SS1
SELECTOR SWITCH
(MAIN/SUB)
R1T
THERMISTOR(AIR)
R2T
THERMISTOR(COIL-1)
SS2
SELECTOR SWITCH
(WIRELESS ADDRESS SET)
R3T
THERMISTOR(COIL-2)
S1L
FLOAT SWITCH
CONNECTOR FOR OPTIONAL PARTS
T1R
TRANSFORMER(220-240V/22V) X33A
CONNECTOR
(ADAPTOR FOR WIRING)
V1TR
PHASE CONTROL CIRCUIT
X1M
TERMINAL STRIP
X35A
CONNECTOR
(GROUP CONTROL ADAPTOR)
X2M
TERMINAL STRIP
SIGNAL RECEIVER CIRCUIT X40A
CONNECTOR
(ON/OFF INPUT FROM OUTSIDE)
SIGNAL TRANSMISSION CIRCUIT
WIRED REMOTE CONTROLLER
X60A
X61A
CONNECTOR
(INTERFACE ADAPTOR
FOR SKYAIR SERIES)
R1T
THERMISTOR(AIR)
SS1
SELECTOR SWITCH(MAIN/SUB)
WIRELESS REMOTE CONTROLLER
(RECEIVER/DISPLAY UNIT)
A3P
PRINTED CIRCUIT BOARD
A4P
PRINTED CIRCUIT BOARD
RC
TC
,
5. GROUND THE SHIELD OF THE REMOTE CONTROLLER CORD TO THE INDOOR UNIT(IN CASE OF USING SHIELD WIRE).
6. SYMBOLS SHOW AS FOLLOWS: RED: RED BLK: BLACK WHT: WHITE YLW: YELLOW PRP: PURPLE GRY: GRAY BLU: BLUE
4. REMOTE CONTROLLER MODEL VARIES ACCORDING TO THE COMBINATION SYSTEM,
CONFIRM ENGINEERING MATERIALS AND CATALOGS, ETC. BEFORE CONNECTING.