SiBE12-933_A
Main Functions
Function and Control
59
COMFORT
AIRFLOW Mode
F(A)TXS20-50G
The vertical swing flap is controlled not to blow the air directly on the person in the room.
The airflow rate is controlled automatically within the following steps.
Cooling: L tap – MH tap (same as AUTOMATIC)
Heating: Equivalent to ML tap – MH tap
The latest command has the priority between POWERFUL and COMFORT AIRFLOW.
F(C)(A)TXG25-50E
The vertical swing flap is controlled not to blow the air directly on the person in the room.
The airflow rate is set to AUTOMATIC.
The airflow rate has the upper limit (M tap) in heating mode.
The latest command has the priority between POWERFUL and COMFORT AIRFLOW.
ATX20-35G
The vertical swing flap is controlled not to blow the air directly on the person in the room.
The airflow rate is controlled automatically within the following steps.
Cooling: L tap – H tap (same as AUTOMATIC)
Heating: LL tap – H tap
The latest command has the priority between POWERFUL and COMFORT AIRFLOW.
3-D Airflow
F(A)TXS20-50G, F(C)(A)TXG25-50E
Alternative repetition of vertical and horizontal swing motions enables uniform air-
conditioning of the entire room. This function is effective for starting the air conditioner.
When the horizontal swing and vertical swing are both set to auto mode, the airflow become
3-D airflow and the horizontal swing and vertical swing motions are alternated. The order of
swing motion is such that it turns counterclockwise, starting from the right upper point as
viewed to the front side of the indoor unit.
Heating
Cooling
Heating
Cooling, Dry
Heating
Cooling
(R8413)
80°
(R4302)
5°
(R3297)
80°
(R3298)
5°
(R9326)
0°
(R9327)
50°
(R1024)
(2)
(3)
(1)
(4)