![background image](http://html.mh-extra.com/html/daikin/2amx40g2v1b/2amx40g2v1b_service-manual_501057253.webp)
SiBE12-933_A
Outdoor Unit
Removal Procedure
243
1.6
Removal of the Thermistors
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the assembly of
thermistor
Be careful not to lose the clip
for the discharge pipe
thermistor.
1
Release the clip and
remove the discharge
pipe thermistor.
2
Cut off the clamp to
remove the heat
exchanger thermistor.
The clamp is always
reserved.
Be careful not to lose the
clips for each thermistor.
3
The outdoor air /
discharge pipe / heat
exchanger thermistors
are united as one
assembly.
4
The figure shows the
arrangement of the
assembly of thermistor
[S90].
2. Remove the liquid / gas
pipe thermistor
1
Remove the liquid / gas
pipe thermistor.
(R7630)
Discharge pipe thermistor
(R7702)
(R7631)
Heat exchanger
thermistor
(R7632)
Outdoor air
thermistor
(R7633)