![background image](http://html.mh-extra.com/html/daikin/2amx40g2v1b/2amx40g2v1b_service-manual_501057033.webp)
SiBE12-933_A
Specifications
Specifications
23
1.3
Indoor Units - Heat Pump
Wall Mounted Type
50Hz 230V
Model
ATX20GV1B
ATX25GV1B
Cooling
Heating
Cooling
Heating
Rated Capacity
2.0kW Class
2.5kW Class
Front Panel Color
White
White
Airflow Rates
m³/min
(cfm)
H
9.1 (321)
9.4 (331)
9.2 (325)
9.7 (342)
M
7.4 (261)
7.8 (276)
7.6 (268)
8.0 (283)
L
5.9 (208)
6.3 (222)
6.0 (212)
6.3 (222)
SL
4.7 (166)
5.5 (194)
4.8 (169)
5.5 (194)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
16
16
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.18
0.18
0.18
0.18
Power Consumption (Rated)
W
40
40
40
40
Power Factor
%
96.6
96.6
96.6
96.6
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
283×770×198
283×770×198
Packaged Dimensions (H×W×D)
mm
263×840×344
263×840×344
Weight
kg
7
7
Gross Weight
kg
11
11
Operation
Sound
H/M/L/SL
dBA
39/33/25/22
39/34/28/25
40/33/26/22
40/34/28/25
Sound Power
H
dBA
55
55
56
56
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D059076
3D059077
Model
ATX35GV1B
Cooling
Heating
Rated Capacity
3.5kW Class
Front Panel Color
White
Airflow Rates
m³/min
(cfm)
H
9.3 (328)
10.1 (356)
M
7.7 (272)
8.4 (295)
L
6.1 (215)
6.7 (235)
SL
4.9 (173)
5.7 (201)
Fan
Type
Cross Flow Fan
Motor Output
W
16
Speed
Steps
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.18
0.18
Power Consumption (Rated)
W
40
40
Power Factor
%
96.6
96.6
Temperature Control
Microcomputer Control
Dimensions (H×W×D)
mm
283×770×198
Packaged Dimensions (H×W×D)
mm
263×840×344
Weight
kg
7
Gross Weight
kg
11
Operation
Sound
H/M/L/SL
dBA
41/34/27/23
41/35/29/26
Sound Power
H
dBA
57
57
Heat Insulation
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
Gas
mm
φ
9.5
Drain
mm
φ
18.0
Drawing No.
3D059078
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3