Main Functions
SiBE12-933_A
58
Function and Control
1.3
Power-Airflow Flaps, Wide-Angle Louvers, Auto-Swing,
COMFORT AIRFLOW Mode and 3-D Airflow
Power-airflow
Flaps
The large flaps send a large volume of air downwards to the floor. The flap provides an optimum
control area in cooling, heating, and dry mode.
Heating Mode
During heating mode, the large flap enables direct warm air straight downwards. The flap
presses the warm air above the floor to reach the entire room.
Cooling / Dry Mode
During cooling / Dry mode, the flap retracts into the indoor unit. Then, cool air can be blown far
and pervaded all over the room.
Wide-Angle
Louvers
The louvres, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Auto-Swing
In case of F(A)TXS20-50G
The following table explains the auto swing process for heating, cooling, dry, and fan :
In case of ATX20-35G
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Cooling / Dry
Heating
Fan
Vertical Swing (up and down)
Horizontal Swing
(right and left: manual)
Cooling / Dry / Fan
Heating
(R8315)
15°
50°
55°
30°
(R8316)
30°
70°
30°
30°
65°
(R8317)
5°
80°
30°
65°
(R8318)
45°
45°
(R9323)
5°
45°
(R9324)
15°
45°
(R9325)
45°
45°