background image

Variant

Supply air

Performance

Size

Air  

connection:

Pa*

l/s

m

3

/h

Total cooling 

capacity 

(W)**

Sound 

level 

(dB(A))

600

125

75

20

72

493

26

600

125

75

25

90

564

28

600

125

75

30

108

631

30

600

160

75

25

90

566

27

600

160

75

35

126

697

30

600

160

75

45

162

809

33

1200

125

75

25

90

882

26

1200

125

75

35

126

1077

28

1200

125

75

45

162

1218

30

1200

160

75

30

108

900

23

1200

160

75

60

216

1375

28

1200

160

75

80

288

1591

34

1800

1800

1800

*Total pressure duct (Pa) 
**Air: 

T

l

=7K / Water: 

T

mk

=8.5K, t

water

=14/17°C

PARASOL

 Zenith b

Integrated comfort module

QUICK GUIDE

 

High performance 4-way distribution comfort module 
with cooling, heating and ventilation

 

Large span between the lowest and highest air flow

 

Few variants for easier sizing and variable air flow 
control

 

Optimised for low energy consumption

 

Manages high air flow at low driving pressure

 

Easy installation on account of low weight, compact 
dimensions and optional air connections on short or 
long sides

 

Stylish design with optional perforation pattern

 

Hygiene design as an option for hospital applications

 

Quick bracket for time saving installation

 

Can be integrated in the WISE-system

 

Upgradable from CAV to VAV

Summary of Contents for ADAPT Parasol b 1200

Page 1: ...twater 14 17 C PARASOL Zenith b Integrated comfort module QUICK GUIDE High performance 4 way distribution comfort module with cooling heating and ventilation Large span between the lowest and highest air flow Few variants for easier sizing and variable air flow control Optimised for low energy consumption Manages high air flow at low driving pressure Easy installation on account of low weight comp...

Page 2: ...ol equipment LUNA 23 Factory fitted accessories for LUNA control equipment 23 Loose accessories 24 Loose accessories conti 25 Complete kit for upgrade to the WISE system 26 Dimensions and weight 27 PARASOL Zenith 600 short side connection or 1 28 PARASOL Zenith 1200 long side connection 2 or 4 29 PARASOL Zenith 1200 short side connection 1 30 PARASOL Zenith with bend 31 Specification 32 Contractor...

Page 3: ...ppreciates Lowest weight on the market simpler and more ergonomic handling Compact dimensions can often be installed in existing roof system without the need of dismantling this Possibility of air connection on the short side faster installation with less material usage Easily accessible water connections access with press coupling tool Easier commissioning select factory setting k factor or adjus...

Page 4: ...cation Parasol Zenith is ideal for use as a standard application in such premises as Offices and conference rooms Classrooms Hotels Restaurants Hospitals Shops Shopping centres Figure 1 Product image PARASOL Zenith 1200 Market based module dimensions The order range includes module dimensions to fit the standardised ceiling measurement c c 600 625 and 675 mm In addition there is a mounting frame f...

Page 5: ...is gives very quiet operation and minimal maintenance requirements Unlike a 2 way air discharge climate beam air distribution to the room occurs from all 4 sides of the unit which means as large areas of the ceiling as possible are used to spread the air thus ensuring comfort in the occupied zone Parasol Zenith has variable k factor setting and large air flow range The product is available both as...

Page 6: ...e if 20 l s supply air comes from the air handling unit then approximately 60 100 l s room air will pass through the exchanger and be tempered Figure 4 Induction principle in Parasol Zenith Condensation free cooling Parasol Zenith has been developed to work condensation free and therefore requires no drainage system or filter Normally inlet temperatures between 14 16 C are used for the cooling wat...

Page 7: ...th VAV for stand alone applications Launched week 17 For more information see the product sheets WISE Parasol Zenith and Parasol Zenith VAV on www swegon com You can also integrate Parasol Zenith as a pure CAV product without motorised damper function in the WISE system This is done by choosing a WISE CU as a fitted accessory This gives additional flexibility to use wireless technology and at the ...

Page 8: ... of room types by being adjusted as required The large work area is made possible by Parasol Zenith being equipped with slots for versatile and easy air flow adjustment This also gives the following advantages Fewer variants through larger air flow range k factor area Products with easy k factor setting on site for quick start of the build Simple commissioning Prerequisites Supply air Cooling wate...

Page 9: ...ll comfort modules contain ADC as standard ADC stands for Anti Draught Control which enables you to set the diffusion pattern of the air being distributed to avoid risk of draught ADC can also be used to reduce the throw length By setting ADC to L shape the distance between two units can be reduced to a minimum and still ensure good comfort A number of ADC sections with nine air deflectors per sec...

Page 10: ...to lower the face plate for high air flow rates maximum capacity induction is still achieved The face plate on PARASOL Zenith is available with four different perforation patterns that make it easily adapta ble to suit different types of ceiling components e g light fittings and extract air diffusers that share the surface of a suspended ceiling A suspended ceiling containing different types of pe...

Page 11: ... Dust particles which fasten on the coil not only result in less capacity but also fail to comply with the hygiene requirements that apply to the room Parasol Zentih has as an option the possibility of fold out coils to meet these requirements In addition to normal cleaning by wiping off dust from the white painted surfaces exactly as you clean other surfaces in the room the option of more thoroug...

Page 12: ...llation example Straight air connection alternative with 90 bend Figure 19 Air connection on the product s short side Figure 20 Air connection on the product s long side Easily accessible water connections The water pipes are very easily accessible which facilitates connection particularly if e g press couplings and associ ated tools are used This saves installation time and simplifies a safe wate...

Page 13: ...it for easier installation PARASOL Z QUICK SUSPENSION KIT consisting of 2 fixed brackets The fixed brackets are fastened to the ceiling The product can then be pushed into place without the use of tools The brackets also feature an integrated fine adjustment of approx 50 mm in height Figure 24 Figure 23 Suspension in four brackets with SYST MS M8 Figure 22 Assembly piece SYST MS M8 1 ceiling mount...

Page 14: ...y fitting cover The sleeve can be removed if necessary and switched with the cover on location if at a late stage you choose to connect on the opposite page Selectable air connection sides Unit Selectable connection side mm side 1 side 2 side 4 600 1200 1800 Connections Water Connect the water pipes using push on compression ring or press couplings Note that compression ring couplings and press co...

Page 15: ...ature differences are always expressed in Kelvin K Supply flow temperature Cooling water Heating water max 60 ºC Cooling water must always be kept at a level that ensures that no condensation is formed Table 1 Cooling capacity for natural convection Unit Cooling capacity W for temperature difference room water Tmk K mm 6 7 8 9 10 11 12 600 28 33 39 44 55 56 62 1200 69 83 97 111 125 141 155 1800 89...

Page 16: ...4 273 319 364 410 455 1 16 20 72 25 144 192 240 288 415 484 553 622 691 2 34 30 108 27 216 288 360 432 510 595 680 765 850 3 57 40 144 29 288 384 480 576 571 666 761 856 951 4 89 45 162 30 324 432 540 648 590 688 786 884 983 5 59 1200 A Ø160 10 36 20 72 96 120 144 275 321 367 413 459 1 16 25 90 23 180 240 300 360 419 489 559 629 699 2 90 40 144 25 288 384 480 576 518 605 691 777 864 4 69 60 216 28...

Page 17: ...l But for older buildings with worse windows it may be necessary to raise the air temperature to compensate for the chilling effect Different operating scenarios can be simulated easily using the Swegon ESBO software to calculate the heat balance where both the room air temperature and operative temperature are specified Supplying heated air from the ceiling results in some stratification of the a...

Page 18: ...144 33 4 86 43 155 35 5 27 600 B Ø160 10 36 20 1 16 20 72 25 2 32 30 108 29 3 49 40 144 32 4 69 45 162 33 5 27 1200 B Ø125 10 36 20 346 336 514 706 922 1130 1 16 20 72 25 350 498 755 1034 1342 1648 2 34 30 108 27 408 587 891 1220 1587 1905 3 57 40 144 29 438 629 947 1292 1665 1996 4 89 45 162 30 453 654 987 1379 1728 2074 5 59 1200 B Ø160 10 36 20 165 235 354 482 637 765 1 16 25 90 23 364 520 780 ...

Page 19: ...de of the k factor table B Read the required k factor on the row in question C Follow the vertical row and read the number of degrees at the bottom D Loosen the screw located in the knob s groove the knob then moves to the fully open position 90 Turn the knob until the marking D reaches the required number of degrees E In the example from the table for a PARASOL Zenith with length 1200 ø125 k fact...

Page 20: ...factor COP Octave band Hz 63 125 250 500 1k 2k 4k 8k 2 23 19 9 9 8 7 11 18 4 22 17 9 8 7 6 9 16 6 23 17 9 8 7 6 9 15 8 23 17 9 8 7 6 8 14 9 9 22 17 9 8 7 5 8 13 Table 9 Natural attenuation ΔL dB PARASOL Zenith 1200 Ø160 K factor COP Octave band Hz 63 125 250 500 1k 2k 4k 8k 2 20 16 10 8 7 7 12 18 4 19 16 10 7 7 6 10 16 6 20 16 10 7 6 5 9 15 8 20 16 9 6 5 4 9 14 10 85 18 16 9 6 5 4 9 13 Table 10 Na...

Page 21: ...or the function WISE dewpoint monitoring When you choose a WISE CU you can easily upgrade the CAV product in the future to a VAV with our upgrade kit see below Control equipment LUNA To control the room temperature Set point value is set on the controller which is mounted on the wall LUNA has four outputs to control heating and cooling actuators LUNA has a built in temperature sensor and possibili...

Page 22: ...w swegon com Condensation guard WISE Dew point regulation The PT1000 sensor measures the supply temperature on water pipes in order to give the function WISE dewpoint monitoring Note that other accessories that measure RH and temperature are needed in combination with the PT1000 sensor to realise this function Occupancy detector WISE SMB WISE SMB measures temperature and detects occupancy and indi...

Page 23: ...C NC Normally Closed For more information about the valve actuator see the separate product data sheet on www swegon com Condensation sensor CG IV CG IV is a condensation sensor with sensor element consisting of a circuit board with gold plated conductive paths that react when condensation occurs between the paths When condensation arises the cooling valve closes the incoming water flow to the pro...

Page 24: ...hoses are also available in various lengths Note that compression ring couplings require support sleeves inside the pipes Example of hoses F1 Flexible hoses with clamping ring couplings F20 Flexible hoses with quick fit couplings push on F30 Flexible hose with quick fit coupling push on at one end and G20ID sleeve nut at the other end Connection piece air double nipple SYST AD1 SYST AD1 is used as...

Page 25: ...zle strips in Parasol Zenith Centring kit SYST CENTRING KIT PARASOL The kit consists of 6 centring rails that can be used to centre the product in specific suspended ceiling systems Transformer SYST TS 1 72 VA Double insulated protective transformer 230 V AC 24 V AC See separate product datasheet at www swegon com 25 23 03 2019 Swegon reserves the right to alter specifications PARASOL Zenith b ...

Page 26: ...e upgrade kit includes motor actuator actuator cable RJ45 cable and screw Upgrade kit WISE CG IV KIT CG IV Ma nual The upgrade kit includes condensation sensor and assembly parts Upgrade kit WISE dew point regulation PT1000 Ma nual The upgrade kit includes temperature sensor PT1000 Upgrade kit WISE SMA The upgrade kit includes WISE SMA incl RJ12 cable and assembly plate Upgrade kit WISE face plate...

Page 27: ...42 667 2017 667 Table 12 Weight Length Type Dim Dry weight Water volume l mm Ø kg cooling heating 600 A 125 12 9 1 08 600 B 125 13 2 0 84 0 34 600 A 160 14 1 1 08 600 B 160 14 4 0 84 0 34 1200 A 125 22 6 2 4 1200 B 125 22 9 1 8 0 7 1200 A 160 24 6 2 4 1200 B 160 24 9 1 8 0 7 1800 A 200 The product is launched week 17 1800 B 200 1800 A 200 1800 B 200 These are examples of the most common sizes of P...

Page 28: ...ø12x1 0 mm Cu B2 Return heating water ø12x1 0 mm Cu Figure 30 Dimensional drawing side view Figure 29 Dimensional drawing top view A2 A1 210 210 592 103 50 137 152 471 507 B2 B1 177 221 250 50 172 202 165 161 592 330 368 638 642 508 592 PARASOL Zenith 600 short side connection or 1 PARASOL Zenith b 28 Swegon reserves the right to alter specifications 23 03 2019 ...

Page 29: ... Supply heating water ø12x1 0 mm Cu B2 Return heating water ø12x1 0 mm Cu Figure 32 Dimensional drawing view from above Air connection on the long side pos 2 Figure 33 Dimensional drawing side view Air connection on the long side pos 2 Ø160 PARASOL Zenith 1200 long side connection 2 or 4 419 177 221 251 137 152 165 161 930 235 368 1192 508 592 29 23 03 2019 Swegon reserves the right to alter speci...

Page 30: ...m Cu B2 Return heating water ø12x1 0 mm Cu Figure 35 Dimensional drawing view from above Air connection on the short side pos 1 Figure 36 Dimensional drawing side view Air connection on the short side pos 1 Ø160 PARASOL Zenith 1200 short side connection 1 A2 A1 210 210 592 103 50 137 152 471 508 B2 B1 930 1239 1241 1192 368 508 165 161 592 177 221 251 50 172 202 PARASOL Zenith b 30 Swegon reserves...

Page 31: ...connection dimensions Unit mm Dimension Ø 600 Ø125 or Ø160 1200 Ø125 or Ø160 1800 Ø200 Figure 37 Dimensional drawing long side connection with bend Ø125 160 200 Unit A B A B A B 600 125 501 160 540 1200 125 501 160 540 1800 200 580 PARASOL Zenith with bend B A A A B A A A 31 23 03 2019 Swegon reserves the right to alter specifications PARASOL Zenith b ...

Page 32: ...8 mm 603 x 603 mm 1213 x 603 mm 617 x 617 mm 1242 x 617 mm 623 x 623 mm 1248 x 623 mm 642 x 642 mm 1292 x 642 mm 667 x 667 mm 1342 x 667 mm Three module unit The product is launched week 17 1784 x 584 mm 1792 x 592 mm 1798 x 598 mm 1823 x 603 mm 1867 x 617 mm 1873 x 623 mm 1942 x 642 mm 2017 x 667 mm The tolerance is 2 mm Function The units can be ordered in various func tional versions A Cooling ...

Page 33: ...Zenith 1800 PARASOL Zenith 1200 Product PARASOL Zenith b aaaa bb ccc d Version Size 1184 x 584 1192 x 592 1198 x 598 1213 x 603 1242 x 617 1248 x 623 1292 x 642 1342 x 667 Function A2 Cooling and supply air serial connected double row coil B2 Cooling heating and supply air serial connected double row coil Dimensions connection sleeves 125 Ø125 connection product height 221 mm 160 Ø160 connection p...

Page 34: ...nt Enclosed design with integrated circulation air opening Air connection on the product s short or long side optional with the opportunity to move the connection Possibility to upgrade from CAV to VAV function Cleanable air duct The product will be Eurovent certified verified cooling capacity according to EN 15116 Colour White RAL 9003 gloss ratio 30 6 Length nominal 1 200 mm Width nominal 600 mm...

Page 35: ...N KIT X pcs The kit consisting of 2 fixed brackets to suspend PARASOL Zenith SYST AD1 X pcs Double nipple for the connection of the air duct to the product s air connection sleeve Dimensions Ø125 and 160 mm SYST CA X pcs 90 duct bend for air connection Nipple connections with seals Dimensions Ø125 and 160 mm CRPc 9 Commissioning damper with perforated damper blade Air tight ness class 0 Dimensions...

Page 36: ...ated circulation air opening Air connection on the product s short or long side optional with the opportunity to move the connection Cleanable air duct The product will be Eurovent certified verified cooling capacity according to EN 15116 Colour White RAL 9003 gloss ratio 30 6 Length nominal 600 1200 1800 mm Width nominal 600 mm Height 220 Ø125 250 Ø160 mm 290 Ø200 Tolerances 2 mm Water connection...

Page 37: ...IT The kit consisting of 2 fixed brackets to suspend PARASOL Zenith X pcs SYST AD1 Double nipple for the connection of the air duct to the product s air connection sleeve X pcs Dimensions Ø125 and 160 mm SYST CA 90 duct bend for air connection X pcs Nipple connections with seals Dimensions Ø125 and 160 mm SYST FH Flexible connection hoses available in different variants X pcs SYST AR 12 Nipple for...