Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 3
Page 3.8.8
>> With HomeSafe emergency function (Post-MOD70-0650-34A)
HS FUEL SHUTOFF
Indicates that the HomeSafe fuel shut-off valve is closed.
▲
WARNING
▲
This may quickly lead to an engine stop if the right fuel tank is
selected.
▲
1 -
FUEL TANK SELECTOR
L
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -
AUX BP switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
●
NOTE
●
Maintain AUX BP switch in ON position for the remainder of the flight.
●
►
Land as soon as practical
◄
If
HS FUEL SHUTOFF
remains ON :
A mechanical failure of the HomeSafe fuel shut-off valve may have occurred.
3 -
FUEL SEL switch
MAN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 -
FUEL TANK SELECTOR
Check L
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
▲
CAUTION
▲
Land as soon as possible to limit fuel imbalance.
▲
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS