Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.10.12
VACUUM LOW
Low vacuum may lead to malfunctioning of leading edge deicing and pressurization.
1 -
Monitor the normal functioning of leading edge deicing and pressurization.
If necessary :
2 -
Altitude
Below 10000 ft
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -
Return to VMC conditions as soon as possible.
►
Fly the airplane
◄
4 -
BLEED switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End of procedure.