Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.3.8
Governor control not operating
►
Fly the airplane
◄
1 -
Continue the flight.
If Np < 1960 RPM :
►
Do not perform a go around
◄
►
Do not use the reverse
◄
In that case, the go-around performance and the reverse efficiency might be lower
than expected.
Repair before further flight.
End of procedure.
Excessive propeller rotation speed
►
Fly the airplane
◄
1 -
Reduce power and airplane speed to avoid propeller rotation speeds higher
than 2050 RPM.
►
Land as soon as possible
◄
►
Do not perform a go around
◄
In that case, the go-around may damage the gear reduction box and the reverse
efficiency might be lower than expected.
Repair before further flight.
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS