Fuel panel
24 -
AUX BP switch
AUTO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 -
AUX BOOST PMP ON
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electric power
26 -
MAIN GEN
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset if necessary
●
NOTE
●
MAIN GEN
normally goes off as soon as
STARTER
goes off.
●
If
MAIN GEN
does not go off :
27 -
Ng
Increase over 70 %
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To start main generator
28 -
Generator and battery AMPS
Check charge
. . . . . . . . . . . . . . . . . . . . .
On EIS of MFD
29 -
Battery and ESS. bus VOLTS
Check voltage
≈
28 Volts
. . . . . . . . . . .
On EIS of MFD
End of procedure.