Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
TR30 - July 2023
Page 3.5.6
Fire or smoke in flight
3/4
►
Continuing
●
NOTE
●
In this configuration, the battery only supplies power to ESS BUS 1,
ESS BUS 2, and BATT BUS, refer to chapter 3.9.
●
If smoke or fire persists:
►
Fly the airplane
◄
16 -
Crash lever
Pull down
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 -
Use the standby instrument (MD302) for:
-
attitude
-
airspeed
-
altitude
-
heading
●
NOTE
●
The internal battery will provide power to the MD302 for one hour.
●
If smoke or fire stops:
18 -
Crash lever
Up
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
●
NOTE
●
This will allow the pilot to use PFD 1 and COM 1.
●
19 -
Use VHF 1 to seek assistance from Air Traffic Control for landing
If not:
20 -
Return to VMC conditions if possible
For approach and landing:
21 -
Perform procedure
Emergency gear extension
. . . . . . . . . . . . . . . . . . . . . . . . .
Refer to chapter 3.7
Continue
►
PIM - DO NOT USE FOR FLIGHT OPERATIONS