Chapter 5 Management of Machine Parameters
When the main shaft often stops at more than 100 degree, the user can decrease
the parameter value. Thus the user can adjust the value to let the main shaft stop
close to 100 degree. The value can be set between 0 and 30.
“Main Motor Para.” is to adjust cooperation between main shaft motor and
machinery parts. The parameter value can be set between 0 and 30, and set as 0 in
most situations. When during braking the main shaft vibrates without moving or
rotates in the reverse direction, or looks like lacking of brake strength, the user
can increase the parameter value.
After adjusting these parameters, the user can press the task swift key on the panel
to return to the main screen. Press the key
and “
”, to check the effects
of the parameter adjustment. If the user is not satisfied with the effects, he can
press the swift key on the panel to return to the parameter setting screen, where he
can adjust the parameter setting again. Close the parameter setting screen in the
end.
4.
Forbidding Design Output
The function is to forbid unauthorized copy of the designs in memory (into the
disk). If the machine administrator set “No Output Design” as “Yes”, other
persons are unable to output the designs to the disk. If the user needs to output, he
has to cancel “No Output Design” first.
5-3
Set User-defined parameter
This function should be used with “select user-defined parameter from all”. “Set
user-defined parameter” makes it easy to set the frequently changed parameters.
The setting should follow the steps as below:
BECS-D16 computerized embroidery machine owner’s manual
71
Summary of Contents for BECS-D16
Page 2: ......