xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
130
DGS-3627:5#show double_vlan Drazen
Command: show double_vlan Drazen
Global Double VLAN : Enabled
====================================================
SPVID : 6
VLAN Name : Drazen
TPID : 0x9200
Uplink Ports :
Access Ports : 4-8
Unknow Ports :
----------------------------------------------------
Total Entries : 1
DGS-3627:5#
enable pvid auto_assign
Purpose
Used to enable auto assignment of PVID.
Syntax
enable pvid auto_assign
Description
If “Auto-assign PVID” is enabled, PVID will be possibly changed
by PVID or VLAN configuration. When a user configures a port to
VLAN
X
’s untagged membership, this port’s PVID will be updated
with VLAN X. In the form of VLAN list command, PVID is updated
with the last item of the VLAN list. When a user removes a port
from the untagged membership of the PVID’s VLAN, the port’s
PVID will be assigned with “default VLAN”. The default setting is
enabled.
Parameters None.
Restrictions Only
administrator-level
and operator-level users can issue this
command.
Example usage:
To enable the auto-assign PVID:
DGS-3627:5#enable pvid auto_assign
Command: enable pvid auto_assign
Success.
DGS-3627:5#
disable pvid auto_assign
Purpose
Used to disable auto assignment of PVID.
Syntax
disable pvid auto_assign
Description
If “auto-assign PVID” is disabled, PVID can only be changed by PVID
configuration (user changes explicitly). The VLAN configuration will
not automatically change PVID. The default setting is enabled.
Parameters None.
Restrictions Only
administrator-level
and operator-level users can issue this
command.
Example usage:
To disable the auto-assign PVID: