DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
398
To view the following window, click
OAM > Ethernet OAM > Ethernet OAM DULD Settings
, as shown below:
Figure 10-26 Ethernet OAM DULD Settings Window
The fields that can be configured in
Ethernet OAM DULD Settings
are described below:
Parameter
Description
Recovery Time
Enter the time interval value used by DULD to decide how long to recover the
disabled port here. When the timer has expired, the disabled port by DULD will
be recovered automatically. 0 represents that this function is disabled. This
value is either 0 seconds or in the range from 60 to 1000000 seconds.
Unit
Select the Switch unit ID that will be used here.
From Port - To Port
Select the Switch port range that will be used here.
Admin State
Select to enable or disable the admin state here. This feature is used to enable
Ethernet OAM unidirectional link detection on the specified port(s).
Action
Select the action that will be taken here. Options to choose from are
Normal
and
Shutdown
.
Discovery Time
Enter the discovery time value here. The range is from 5 to 65535 seconds. By
default, this value is 5 seconds. If the OAM discovery does not successfully
negotiate before discovery time expired, OAM unidirectional link detection will
start.
Click the
Apply
button to accept the changes made.
The fields that can be configured in
Ethernet OAM DULD Table
are described below:
Parameter
Description
Unit
Select the Switch unit ID that will be used here.
From Port - To Port
Select the Switch port range that will be used here.
Click the
Find
button to locate a specific entry based on the information entered.
Click the
Show All
button to display all the entries.