DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
394
Figure 10-223 Ethernet OAM Configuration Settings Window
The fields that can be configured in
Ethernet OAM Configuration Settings
are described below:
Parameter
Description
Unit
Select the Switch unit ID that will be used here.
From Port - To Port
Select the Switch port range that will be used here.
Dying Gasp
Select to enable or disable the dying gasp feature here. This feature is used to
configure the capability of the dying gasp event. If the capability for the dying
gasp event is disabled, the port will never send out OAM PDUs with the dying
gasp event bit set when an unrecoverable local failure condition has occurred.
Critical Event
Select to enable or disable the critical event feature here. This feature is used
to configure the capability of the critical event. If the capability for a critical
event is disabled, the port will never send out OAM PDUs with critical event bit
set when an unspecified critical event has occurred.
Link Monitor
Select the link monitor feature here. Options to choose from are
Error Symbol
,
Error Frame
,
Error Frame Seconds
, and
Error Frame Period
.
•
Error Symbol
- This feature is used to enable notifying the Ethernet OAM
error symbol event and configure the monitor threshold and window on the
specified port.
•
Error Frame
- This feature is used to enable notifying the Ethernet OAM
error frame event and configure the monitor threshold and window on the
specified port.
Summary of Contents for DGS-3130 Series
Page 1: ......