INSTALLATION AND OPERATION MANUAL
CNGE24MS-OB(M,S)
TECH SUPPORT: 1.888.678.9427
Label
Description
Port
This is the logical port number for this row.
Link
The current link state is displayed graphically. Green indicates the link is up and red that
it is down.
Current Link
Speed
Provides the current link speed of the port.
Configured Link
Speed
Select any available link speed for the given switch port.
Auto Speed selects the highest speed that is compatible with a link partner.
Disabled disables the switch port operation.
Flow Control
When Auto Speed is selected for a port, this section indicates the flow control
capability that is advertised to the link partner.
When a fixed-speed setting is selected, that is what is used. The Current Rx column
indicates whether pause frames on the port are obeyed, and the Current Tx column
indicates whether pause frames on the port are transmitted. The Rx and Tx settings are
determined by the result of the last Auto-Negotiation.
Check the configured column to use flow control. This setting is related to the setting
for Configured Link Speed.
Maximum Frame Enter the maximum frame size allowed for the switch port, including FCS. The allowed
range is 1518 bytes to 9600 bytes.
Power Control
Allows for changing the power savings mode parameters per port.
Disabled: All power savings mechanisms disabled.
ActiPHY: Link down power savings enabled.
PerfectReach: Link up power savings enabled.
Enabled: Both link up and link down power savings enabled.
Save
Select to save changes.
Reset
Select to undo any changes made locally and revert to previously saved values.
Refresh
Select to refresh the page. Any changes made locally will be undone.