![Comnet CNGE20MS Installation And Operation Manual Download Page 143](http://html1.mh-extra.com/html/comnet/cnge20ms/cnge20ms_installation-and-operation-manual_2644359143.webp)
INS_CNGE24MS-OB(M,S)_REV–
09/12/12 PAGE 143
INSTALLATION AND OPERATION MANUAL
CNGE24MS-OB(M,S)
TECH SUPPORT: 1.888.678.9427
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (C-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server/Client/Relay
Network Redundancy
C-Ring
MSTP (RSTP/STP compatible)
RS-232 Serial Console Port RS-232 in RJ45 connector with console cable. 115200bps, 8, N, 1
Fault contact
Relay
Relay output to carry capacity of 1A at 24VDC
Power
Redundant Input power
Dual 100~240V AC power inputs in single power socket
Power consumption (Typ.)
25 Watts
Overload current protection Present
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
300 × 165 × 88 mm (11.8 × 6.49 × 3.46 in)
Weight (g)
2300 g
Environmental
Storage Temperature
-40 to 85ºC (-40 to 185ºF)
Operating Temperature
-40 to 75ºC (-40 to 167ºF )
Operating Humidity
5% to 95% Non-condensing
Regulatory approvals
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD)
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
Safety
EN60950-1
Warranty
Lifetime