Event
Event>
Configuration
Syslog SystemStart [enable|disable]
Syslog PowerStatus [enable|disable]
Syslog SnmpAuthenticationFailure [enable|disable]
Syslog RingTopologyChange [enable|disable]
Syslog Port [<port_list>] [disable|linkup|linkdown|both]
SMTP SystemStart [enable|disable]
SMTP PowerStatus [enable|disable]
SMTP SnmpAuthenticationFailure [enable|disable]
SMTP RingTopologyChange [enable|disable]
SMTP Port [<port_list>] [disable|linkup|linkdown|both]
DHCPServer
DHCPServer>
Mode [enable|disable]
Setup [<ip_start>] [<ip_end>] [<ip_mask>] [<ip_router>] [<ip_dns>] [<ip_tftp>] [<lease>]
[<bootfile>]
Ring
Ring>
Mode [enable|disable]
Master [enable|disable]
1stRingPort [<port>]
2ndRingPort [<port>]
Couple Mode [enable|disable]
Couple Port [<port>]
Dualhoming Mode [enable|disable]
Dualhoming Port [<port>]
RCS
RCS>
Mode [enable|disable]
Add [<ip_addr>] [<port_list>] [web_on|web_off] [telnet_on|telnet_off] [snmp_on|snmp_off]
Del <index>
Configuration
SFP
SFP>
syslog [enable|disable]
temp [<temperature>]
Info