Comnet CNGE20MS Installation And Operation Manual Download Page 1

INSTALLATION AND OPERATION MANUAL 

CNGE24MS-OB(M,S)

INDUSTRIAL 24-PORT ALL GIGABIT MANAGED ETHERNET SWITCH  

WITH 16 TX PORTS AND 8 SFP PORTS PLUS OPTICAL BYPASS

The ComNet CNGE24MS-OB is a Managed Ethernet Switch with sixteen 
10/100/1000 Mbps TX ports and eight 100/1000 Mbps SFP* ports that use 
ComNet SFPs for fiber type, connector type and distance. This switch also 
includes two sets of bypass ports that ensure network integrity during power  
loss or maintenance. The CNGE24MS-OB is IEEE802.3-compliant and offers 
multiple Ethernet redundancy protocols (ComRing, C-Ring, and MSTP/RSTP/
STP) which protect your applications from network interruptions or temporary 
malfunctions by redirecting transmission within the network. Unlike most 

 

Ethernet switches, these environmentally hardened units are designed for 
deployment in difficult operating environments, and are available for use 

 

with either conventional CAT-5e copper or optical transmission media.

Rev. 11.18.16

Summary of Contents for CNGE20MS

Page 1: ...sets of bypass ports that ensure network integrity during power loss or maintenance The CNGE24MS OB is IEEE802 3 compliant and offers multiple Ethernet redundancy protocols ComRing C Ring and MSTP RST...

Page 2: ...fety Information 3 Overview 4 Introduction 4 Software Features 5 Hardware Features 5 Hardware Overview 6 Front Panel 6 Front Panel LEDs 7 Rack mount Installation 8 Wiring 9 Fault Relay 9 AC Power Conn...

Page 3: ...fications or repairs done by persons other than ComNet approved personnel and this warranty does not apply to ComNet products that are misused abused improperly installed or damaged by accidents Pleas...

Page 4: ...678 9427 Overview Introduction The CNGE24MS OB M S is powerful managed Ethernet switch that has many features These switches can work under a wide temperature range dusty environment and humidity cond...

Page 5: ...o segregate and secure network traffic Radius centralized password management SNMPv3 encrypted authentication and access security RSTP IEEE 802 1w Quality of Service IEEE 802 1p for real time traffic...

Page 6: ...two duplex or four simplex ports Copper Ports 16 10 100 1000BASE T X Console Use RS 232 with RJ 45 connector to manage switch 1 2 3 4 5 6 7 8 9 10 11 12 13 CNGE24MS OB M S Front Panel 1 Fiber bypass...

Page 7: ...erating in Ring Master Mode Ring Green On Ring enabled Fault Amber On Fault relay Power failure or Port down fail Gigabit Ethernet ports LNK ACT Green Blinking Data transmitted On Port is Connected Fu...

Page 8: ...acturer Reduced Air Flow Make sure the amount of air flow required for safe operation of the equipment is not compromised during installation Mechanical Loading Make sure the mounting of the equipment...

Page 9: ...e wiring could overheat causing serious damage to your equipment 4 Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are p...

Page 10: ...N AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 AC Power Connection For power supply simply insert the AC power cable to the power connector at the back of the switch and turn on th...

Page 11: ...r hubs Please refer to the following table for cable specifications Cable Type Max Length Connector 10BASE T CAT3 CAT4 CAT5 100 UTP 100m 328ft RJ 45 100BASE TX CAT5 100 UTP UTP 100m 328ft RJ 45 1000BA...

Page 12: ...ble below shows the 10 100BASE T X MDI and MDI X port pin outs Pin Number MDI port MDI X port 1 TD transmit RD receive 2 TD transmit RD receive 3 RD receive TD transmit 4 Not used Not used 5 Not used...

Page 13: ...without bypass function the device will lose connection if the switch loses power as traffic will not be able to flow through the link as shown in the figure below PC1 Other Switch PC2 Packet Packet S...

Page 14: ...onitor port However the fiber port will not have bypass ability when the device is down Console Cable The CNGE24MS OB M S switch can be managed by the console port The DB 9 to RJ 45 cable can be found...

Page 15: ...itted from DCE Device 3 Transmitted Data Transmitted from DTE Device Received Data Received by DCE Device 4 DTE Ready Transmitted from DTE Device DTE Ready Received by DCE Device 5 Signal Ground Signa...

Page 16: ...lorer The Web Based Management function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy...

Page 17: ...INS_CNGE24MS OB M S _REV 09 12 12 PAGE 17 INSTALLATION AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 Login screen Main Interface Main interface...

Page 18: ...this is the node s fully qualified domain name A domain name is a text string drawn from the alphabet A Z a z digits 0 9 minus sign No space characters are permitted as part of a name The first charac...

Page 19: ...ord required to access the web pages or log in from the CLI Label Description Old Password Enter the current system password If this is incorrect the new password will not be set New Password The syst...

Page 20: ...od can be set to one of the following values none authentication is disabled and login is not possible local use the local user database on the switch for authentication radius use a remote RADIUS ser...

Page 21: ...g you do not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be display in this column The default IP is 192 168 10 1 IP Mask Assign the sub...

Page 22: ...ach field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand way of representing multiple 16 bit groups of contiguous zeros but it can appear only once...

Page 23: ...ode operation Disabled Disable HTTPS mode operation Save Select to save changes Reset Select to undo any changes made locally and revert to previously saved values SSH Label Description Mode Indicates...

Page 24: ...Parameters This page allows the user to inspect and configure the current LLDP port settings Label Description Enabled The switch will send out LLDP information and will analyze LLDP information rece...

Page 25: ...by the neighbor unit Port Description Port Description is the port description advertised by the neighbor unit System Capabilities System Capabilities describes the neighbor unit s capabilities The p...

Page 26: ...Label Description Neighbor entries were last changed at Shows the time for when the last entry was last deleted or added It is also shows the time elapsed since last change was detected Total Neighbo...

Page 27: ...d or when the entry ages out TLVs Discarded Each LLDP frame can contain multiple pieces of information known as TLVs TLV is short for Type Length Value If a TLV is malformed it is counted and discarde...

Page 28: ...e a DHCP server DHCP Dynamic Client List When the DHCP server function is activated the system will collect the DHCP client information and display in here DHCP Client List You can assign the specific...

Page 29: ...OB M S _REV 09 12 12 PAGE 29 INSTALLATION AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 Port Setting Port Control This page displays current port configurations Ports can also be co...

Page 30: ...hat is used The Current Rx column indicates whether pause frames on the port are obeyed and the Current Tx column indicates whether pause frames on the port are transmitted The Rx and Tx settings are...

Page 31: ...ddress The IP address can be used to calculate the destination port for the frame Check to enable the use of the IP Address or uncheck to disable By default IP Address is enabled TCP UDP Port Number T...

Page 32: ...port from the aggregation By default no ports belong to any aggregation group Only full duplex ports can join an aggregation and ports must be in the same speed in each group Key The Key value incurre...

Page 33: ...d is shown as isid aggr id and for GLAGs as aggr id Partner System ID The system ID MAC address of the aggregation partner Partner Key The Key that the partner has assigned to this aggregation ID Last...

Page 34: ...t link is down Backup means that the port could not join the aggregation group but will join if other port leaves Meanwhile it s LACP status is disabled Key The key assigned to this port Only ports wi...

Page 35: ...itch port number LACP TransmittedShows how many LACP frames have been sent from each port LACP Received Shows how many LACP frames have been received at each port Discarded Shows how many unknown or i...

Page 36: ...d Ring Port The backup port when this switch is Ring Master Coupling Ring Mark to enable Coupling Ring Coupling Ring can be used to divide a big ring into two smaller rings to avoid effecting all swit...

Page 37: ...e failure The switch supports the function and interface for setting the switch as the ring master or not The ring master can negotiate and place command to other switches in the X Ring group If there...

Page 38: ...maximum age of the information transmitted by the Bridge when it is the Root Bridge Valid values are in the range 6 to 40 seconds and MaxAge must be FwdDelay 1 2 Maximum Hop Count This defines the in...

Page 39: ...hare spanning trees for MSTI s Intra region The name can have a maximum of 32 characters Configuration Revision The revision of the MSTI configuration named above This must be an integer between 0 and...

Page 40: ...y change them as well Label Description MSTI The bridge instance The CIST is the default instance which is always active Priority Controls the bridge priority Lower numerical values have better priori...

Page 41: ...on Port The switch port number of the logical STP port STP Enabled Controls whether STP is enabled on this switch port Path Cost Controls the path cost incurred by the port The Auto setting will set t...

Page 42: ...panning tree connectivity It can be set by a network administrator to prevent bridges external to a core region of the network influencing the spanning tree active topology possibly because those brid...

Page 43: ...ings are stack global Label Description Port The switch port number of the corresponding STP CIST and MSTI port Path Cost Controls the path cost incurred by the port The Auto setting will set the path...

Page 44: ...ge ID The Bridge ID of this Bridge instance Root ID The Bridge ID of the currently elected root bridge Root Port The switch port currently assigned the root port role Root Cost Root Path Cost For the...

Page 45: ...gical STP port CIST Role The current STP port role of the CIST port The port role can be one of the following values AlternatePort BackupPort RootPort DesignatedPort State The current STP port state o...

Page 46: ...BPDU s received transmitted on the port STP The number of legacy STP Configuration BPDU s received transmitted on the port TCN The number of legacy Topology Change Notification BPDU s received transmi...

Page 47: ...D The VLAN ID for the entry VLAN Name The descriptive name for the entry Port Members Checkmarks indicate which ports are members of the entry Check or uncheck as needed to modify the entry Adding a N...

Page 48: ...INS_CNGE24MS OB M S _REV 09 12 12 PAGE 48 INSTALLATION AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 VLAN Port Configuration...

Page 49: ...untagged frames received on the port are discarded By default the field is set to All Port VLAN Mode Configures the Port VLAN Mode The allowed values are None or Specific This parameter affects VLAN i...

Page 50: ...obtain a tag based on PVID and is forwarded When the port received tagged frames 1 If a tagged frame with TPID 0x8100 it is forwarded 2 If the TPID of tagged frame is not 0x8100 ex 0x88A8 it will be...

Page 51: ...ID 8100 Packet VID 5 TPID 8100 VID PVID TPID 8100 Packet VID 5 TPID 88A8 Packet Discarded QinQ S custom port is used for user defined TPID If the Ethertype for Custom S ports is configured to 8123 the...

Page 52: ...AN Access Mode Setting P7 P7 P2 P2 P1 P1 P8 P8 CNGE24MS OB M S Switch A CNGE24MS OB M S Switch B CNGE24MS OB M S Switch C VLAN Trunk 10 20 VLAN 10 VLAN 10 VLAN 20 VLAN 20 VLAN Trunk 10 20 In the topol...

Page 53: ...Trunk mode P7 P7 P2 P2 P1 P1 P8 P8 CNGE24MS OB M S Switch A CNGE24MS OB M S Switch B CNGE24MS OB M S Switch C VLAN Trunk 10 20 VLAN 10 VLAN 10 VLAN 20 VLAN 20 VLAN Trunk 10 20 In the topology above fo...

Page 54: ...d 10 20 Configure the VLAN for the Switch as shown VLAN QinQ mode Below is an example of the VLAN QinQ Mode which is typically used in an environment with unknown VLAN VLAN X Unknown VLAN P2 P2 P1 P1...

Page 55: ...B M S _REV 09 12 12 PAGE 55 INSTALLATION AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 VLAN Management VLAN ID Setting If Management VLAN is set only the same VLAN ID port can contr...

Page 56: ...elete Check to delete the entry It will be deleted during the next save Private VLAN ID Indicates the ID of this particular private VLAN Port Members A row of check boxes for each port is displayed fo...

Page 57: ...OB M S TECH SUPPORT 1 888 678 9427 Label Description Port Members A check box is provided for each port of a private VLAN When checked port isolation is enabled for that port When unchecked port isol...

Page 58: ...e allowed content is the ASCII characters from 33 to 126 The field only suits to SNMPv1 and SNMPv2c SNMPv3 is using USM for authentication and privacy and the community string will associated with SNM...

Page 59: ...rds represented as eight fields of up to four hexadecimal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand w...

Page 60: ...Security Engine ID is enabled the ID will be probed automatically Otherwise the ID specified in this field is used The string must contain an even number between 10 and 64 hexadecimal digits but all z...

Page 61: ...ty model that this entry should belong to Possible security models are NoAuth NoPriv None authentication and none privacy Auth NoPriv Authentication and none privacy Auth Priv Authentication and priva...

Page 62: ...Indicates the security model that this entry should belong to Possible security models are v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Name A string iden...

Page 63: ...d content is the ASCII characters from 33 to 126 View Type Indicates the view type that this entry should belong to Possible view types are included An optional flag to indicate that this view subtree...

Page 64: ...models are any Accepted any security model v1 v2c usm v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Level Indicates the security model that this entry sho...

Page 65: ...ets per second The configuration indicates the permitted packet rate for unicast multicast or broadcast traffic across the switch Note Frames which are sent to the CPU of the switch are always limited...

Page 66: ...ro has the lowest priority If the port is VLAN aware and the frame is tagged then the frame is classified to a QoS class that is based on the PCP value in the tag as shown below Otherwise the frame is...

Page 67: ...ll frames are classified to a PCP value If the port is VLAN aware and the frame is tagged then the frame is classified to the PCP value in the tag Otherwise the frame is classified to the default PCP...

Page 68: ...QoS Egress Port Tag Remarking for all switch ports Label Description Port The logical port for the settings contained in the same row Click on the port number in order to configure tag remarking Mode...

Page 69: ...4 different values Disable No Ingress DSCP Classification DSCP 0 Classify if incoming or translated if enabled DSCP is 0 Selected Classify only selected DSCP for which classification is enabled as spe...

Page 70: ...rols whether the policer is enabled on this switch port Rate Controls the rate for the policer The default value is 500 This value is restricted to 100 1000000 when the Unit is kbps or fps and it is r...

Page 71: ...number for which the configuration below applies Enable E Controls whether the queue policer is enabled on this queue Port Scheduler This page provides an overview of QoS Egress Port Schedulers for al...

Page 72: ...al queue shaper rate e g 800 Mbps Qn Shows disabled or actual port shaper rate e g 800 Mbps DSCP Based QoS This page allows you to configure the basic QoS DSCP based QoS Ingress Classification setting...

Page 73: ...he DSCP for QoS class and DPL map There are two configuration parameters for DSCP Translation 1 Translate 2 Classify 1 Translate DSCP at Ingress side can be translated to any of 0 63 DSCP values 2 Cla...

Page 74: ...24MS OB M S TECH SUPPORT 1 888 678 9427 DSCP Classification This page allows you to configure the mapping of QoS class and Drop Precedence Level to DSCP value Label Description QoS Class Actual QoS cl...

Page 75: ...escribed as below Tag Value of Tag field can be Any Untag or Tag VID Valid value of VLAN ID can be any value in the range 1 4095 or Any user can enter either a specific value or a range of VIDs PCP Pr...

Page 76: ...read from left to right all bits following the first zero must also be zero DSCP Diffserv Code Point value DSCP It can be a specific value range of values or Any DSCP values are in the range 0 63 inc...

Page 77: ...678 9427 QoS Counters This page provides statistics for the different queues for all switch ports Label Description Port The logical port for the settings contained in the same row Qn There are 8 QoS...

Page 78: ...s IPv6 The QCE will match only IPV6 frames Port Indicates the list of ports configured with the QCE Action Indicates the classification action taken on ingress frame if parameters configured are match...

Page 79: ...Enable the Global IGMP Snooping Unregistered IPMC Flooding enabled Enable unregistered IPMC traffic flooding Router Port Specify which ports act as router ports A router port is a port on the Etherne...

Page 80: ...s allow the user to select the starting point in the VLAN Table Clicking the Refresh button will update the displayed table starting from that or the next closest VLAN Table match The will use the las...

Page 81: ...Querier Status Show the Querier status is ACTIVE or IDLE Querier Receive The number of Transmitted Queries V1 Reports Receive The number of Received V1 Reports V2 Reports Receive The number of Receive...

Page 82: ...PORT 1 888 678 9427 IGMP Snooping Groups Information Entries in the IGMP Group Table are shown on this page The IGMP Group Table is sorted first by VLAN ID and then by group Label Description VLAN ID...

Page 83: ...apply to this port The allowed values are Disabled or the values 1 through 15 The default value is Disabled Port Copy Select which port frames are copied to The allowed values are Disabled or a speci...

Page 84: ...ers Configure the rate limiter for the ACL of the switch Label Description Rate Limiter ID The rate limiter ID for the settings contained in the same row Rate The rate unit is packet per second pps co...

Page 85: ...l equal to 0600 hexadecimal ARP Only ARP frames can match this ACE Notice the ARP frames won t match the ACE with Ethernet type IPv4 Only IPv4 frames can match this ACE Notice the IPv4 frames won t ma...

Page 86: ...or the SMAC filter you can enter a specific source MAC address The legal format is xx xx xx xx xx xx A frame that hits this ACE matches this SMAC value DMAC Filter Specify the destination MAC filter f...

Page 87: ...specific VLAN ID with this ACE choose this value A field for entering a VLAN ID number appears VLAN ID When Specific is selected for the VLAN ID filter you can enter a specific VLAN ID number The allo...

Page 88: ...ol value you can enter a specific value The allowed range is 0 to 255 A frame that hits this ACE matches this IP protocol value IP TTL Specify the Time to Live settings for this ACE zero IPv4 frames w...

Page 89: ...dotted decimal notation SIP Mask When Network is selected for the source IP filter you can enter a specific SIP mask in dotted decimal notation DIP Filter Specify the destination IP filter for this AC...

Page 90: ...Sender IP Address When Host or Network is selected for the sender IP filter you can enter a specific sender IP address in dotted decimal notation Sender IP Mask When Network is selected for the sende...

Page 91: ...y Any Any value is allowed don t care Ethernet Specify whether frames can hit the action according to their ARP RARP protocol address space PRO settings 0 ARP RARP frames where the PRO is equal to IP...

Page 92: ...Destination Filter Specify the TCP UDP destination filter for this ACE Any No TCP UDP destination filter is specified TCP UDP destination filter status is don t care Specific If you want to filter a...

Page 93: ...mes where the URG field is set must be able to match this entry Any Any value is allowed don t care AAA Common Server Configuration This page allows you to configure the Authentication Servers Label D...

Page 94: ...cation Server If the port is set to 0 zero the default port 1812 is used on the RADIUS Authentication Server Secret The secret up to 29 characters long shared between the RADIUS Authentication Server...

Page 95: ...is server Status The current status of the server This field takes one of the following values Disabled The server is disabled Not Ready The server is enabled but IP communication is not yet up and ru...

Page 96: ...the following values Disabled The server is disabled Not Ready The server is enabled but IP communication is not yet up and running Ready The server is enabled IP communication is up and running and t...

Page 97: ...h between the backend servers to show details for The statistics map closely to those specified in RFC4668 RADIUS Authentication Client MIB Use the server select box to switch between the backend serv...

Page 98: ...N MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 Label Description Packet Counters RADIUS accounting server packet counter There are five receive and four transmit counters Other Info This section...

Page 99: ...r are RADIUS packets RADIUS packets also encapsulate EAP PDUs together with other attributes like the switch s IP address name and the supplicant s port number on the switch EAP is very flexible in th...

Page 100: ...ADIUS server must be configured accordingly When authentication is complete the RADIUS server sends a success or failure indication which in turn causes the switch to open up or block traffic for that...

Page 101: ...iod This setting applies to the following modes i e modes using the Port Security functionality to secure MAC addresses MAC Based Auth When the NAS module uses the Port Security module to secure MAC a...

Page 102: ...ovide valid credentials within a certain amount of time another supplicant will get a chance Once a supplicant is successfully authenticated only that supplicant will be allowed access This is the mos...

Page 103: ...take effect Reauthenticate Schedules a reauthentication whenever the quiet period of the port runs out EAPOL based authentication For MAC based authentication reauthentication will be attempted immed...

Page 104: ...2 1X statistics for a specific switch port running port based authentication For MAC based ports it shows selected backend server RADIUS Authentication Server statistics only Use the port select box t...

Page 105: ...ion Backend Server Counters These backend RADIUS frame counters are available for the following administrative states 802 1X MAC based Auth Last Supplicant Client Info Information about the last suppl...

Page 106: ...lt event is happened the Fault LED in switch panel will light up and the electric relay will signal at the same time The following table describes the labels in this screen Label Description Power Fai...

Page 107: ...de operation When the mode operation is enabled the syslog message will send out to syslog server The syslog protocol is based on UDP communication and received on UDP port 514 and the syslog server w...

Page 108: ...checked when SYSLOG is disabled System Warning Event Selection interface The following table describes the labels in this screen Label Description System Cold Start Alert when system restart Power St...

Page 109: ...or entries in the dynamic MAC Table and configure the static MAC table here Aging Configuration By default dynamic entries are removed from the MAC after 300 seconds This removal is also called aging...

Page 110: ...ble before changing to secure learning mode otherwise the management link is lost and can only be restored by using another non secure port or by connecting to the switch via the serial interface Stat...

Page 111: ...arting point in the MAC Table Clicking the Refresh button will update the displayed table starting from that or the closest next MAC Table match In addition the two input fields will upon a Refresh bu...

Page 112: ...mplete transmissions per port Drops The number of frames discarded due to ingress or egress congestion Filtered The number of received frames filtered by the forwarding process Auto Refresh Check this...

Page 113: ...t packets Rx and Tx Broadcast The number of received and transmitted good and bad broadcast packets Rx and Tx Pause A count of the MAC Control frames received or transmitted on this port that have an...

Page 114: ...Label Description Tx Drops The number of frames dropped due to output buffer congestion Tx Late Exc Coll The number of frames dropped due to excessive or late collisions Short frames are frames that...

Page 115: ...es from ports that have either source rx or destination tx mirroring enabled are mirrored to this port Disabled disables mirroring Label Description Port The logical port for the settings contained in...

Page 116: ...r level of the system log All All levels Time The time of the system log entry Message The MAC Address of this switch Auto Refresh Check this box to enable an automatic refresh of the page at regular...

Page 117: ...refreshes automatically and you can view the cable diagnostics results in the cable status table Note that VeriPHY is only accurate for cables of length 7 140 meters 10 and 100 Mbps ports will be link...

Page 118: ...PAGE 118 INSTALLATION AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 SFP Monitor The DDM function allows an SFP module which supports DDM function measure the temperature of the appa...

Page 119: ...y until responses to all packets are received or until a timeout occurs PING6 server 10 10 132 20 64 bytes from 10 10 132 20 icmp_seq 0 time 0ms 64 bytes from 10 10 132 20 icmp_seq 1 time 0ms 64 bytes...

Page 120: ...OB M S _REV 09 12 12 PAGE 120 INSTALLATION AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 IPv6 Ping PING6 server 192 168 10 1 sendto sendto sendto sendto sendto Sent 5 packets receiv...

Page 121: ...able the 1 pps clock input 3 Disable Disable the 1 pps clock in out put External Enable This Selection box will allow you to configure the External Clock output The following values are possible 1 Tru...

Page 122: ...ents and Pdelay_Resp events are used Clock Identity It shows unique clock identifier One Way If true one way measurements are used This parameter applies only to a slave In one way mode no delay measu...

Page 123: ...o reboot device No Select to return to the Port State page without rebooting Factory Defaults You can reset the configuration of the stack switch on this page Only the IP configuration is retained Lab...

Page 124: ...management You can use console or telnet to management switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before Configuring by RS 232 serial console use an RJ45 to DB9 F cabl...

Page 125: ...INS_CNGE24MS OB M S _REV 09 12 12 PAGE 125 INSTALLATION AND OPERATION MANUAL CNGE24MS OB M S TECH SUPPORT 1 888 678 9427 Step 2 Input a name for new connection Step 3 Select the COM port number...

Page 126: ...888 678 9427 Step 4 The COM port properties setting 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appear Use...

Page 127: ...Address 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of...

Page 128: ...Log log_id all info warning error clear IP IP Configuration DHCP enable disable Setup ip_addr ip_mask ip_router vid Ping ip_addr_string ping_length SNTP ip_addr_string Port port Configuration port_lis...

Page 129: ...list all tagged untagged IngressFilter port_list enable disable tx_tag port_list untag_pvid untag_all tag_all PortType port_list unaware c port s port s custom port EtypeCustomSport etype Add vid name...

Page 130: ...y switch auth Configuration Method console telnet ssh web none local radius enable disable Security Switch SSH Security switch ssh Configuration Mode enable disable Security Switch HTTPS Security swit...

Page 131: ...HCP Dynamic Host Configuration Protocol Security Network Psec Security Network Psec Switch port_list Port port_list Security Network NAS Security Network NAS Configuration port_list Mode enable disabl...

Page 132: ...p_type icmp_code ip_flags udp sip dip sport dport ip_flags tcp sip dip sport dport ip_flags tcp_flags permit deny rate_limiter port_redirect mirror logging shutdown Delete ace_id Lookup ace_id Clear S...

Page 133: ...clear Msti Add msti vid Port Configuration port_list Port Mode port_list enable disable Port Edge port_list enable disable Port AutoEdge port_list enable disable Port P2P port_list enable disable aut...

Page 134: ...tion dscp_list trans_dscp DSCP Trust dscp_list enable disable DSCP Classification Mode dscp_list enable disable DSCP Classification Map class_list dpl_list dscp DSCP EgressRemap dscp_list dpl_list dsc...

Page 135: ...ort_list macbased auto authorized unauthorized Authenticate port_list now Reauthentication enable disable Period reauth_period Timeout eapol_timeout Statistics port_list clear eapol radius Clients por...

Page 136: ...itch port port policy policy vid tag_prio dmac_type etype etype smac dmac arp sip dip smac arp_opcode arp_flags ip sip dip protocol ip_flags icmp sip dip icmp_type icmp_code ip_flags udp sip dip sport...

Page 137: ...elete index Community Lookup index User Add engineid user_name MD5 SHA auth_password DES priv_password User Delete index User Changekey engineid user_name auth_password priv_password User Lookup index...

Page 138: ...tDataSet clockinst port_list announceintv announceto syncintv delaymech minpdelayreqintv delayasymmetry ingressLatency LocalClock clockinst update show ratio clockratio Filter clockinst def_delay_filt...

Page 139: ...isable Flooding igmp enable disable VLAN Add igmp vid VLAN Delete igmp vid State igmp vid enable disable Querier igmp vid enable disable Fastleave igmp port_list enable disable Router igmp port_list e...

Page 140: ...sable SMTP SnmpAuthenticationFailure enable disable SMTP RingTopologyChange enable disable SMTP Port port_list disable linkup linkdown both DHCPServer DHCPServer Mode enable disable Setup ip_start ip_...

Page 141: ...mber Port DDOS Filter port_list source destination Port DDOS Action port_list do_nothing block_1_min block_10_mins block shutdown only_log reboot_device Port DDOS Status port_list Port Alive Mode port...

Page 142: ...ss of Service IEEE 802 1Q for VLAN Tagging IEEE 802 1w for RSTP Rapid Spanning Tree Protocol IEEE 802 1s for MSTP Multiple Spanning Tree Protocol IEEE 802 1x for Authentication IEEE 802 1AB for LLDP L...

Page 143: ...Console Port RS 232 in RJ45 connector with console cable 115200bps 8 N 1 Fault contact Relay Relay output to carry capacity of 1A at 24VDC Power Redundant Input power Dual 100 240V AC power inputs in...

Page 144: ...CH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET MECHANICAL INSTALLATION INSTRUCTIONS...