47
timer mode
By pressing the remote
and
buttons the parking lights will flash 4 times and then start the
vehicle and run for the set duration. The remote start can be shut off by the remote by pressing the
remote start button
and remain in timer mode, but if any other shut down zones or the ignition
becomes active the timer mode will cancel.
1. Press Timer mode buttons.
2. The vehicle will confirm with 4 parking light flashes.
3. A 1-second delay will start.
4. The system will start the car and will run for the specified duration, unless shut down by the
remote start button
. If shut down with the remote start button
the system will remain in
timer mode.
5. The system will start every 3 hours until canceled by the brake, hood, or neutral safety shut-down
wires.
To exit timer mode, turn the ignition switch on any time the engine is not running. The parking lights
will flash 4 times, indicating timer mode has been exited.
5. The system will start every 3 hours until canceled by the brake, hood, or neutral safety shut-down
wires.
table of zones
When using the Diagnostic functions, use the Table of Zones to see which input has triggered the sys-
tem. It is also helpful in deciding which input to use when connecting optional sensors and switches.
N
NO
OTTEE:: The warning response does not report on the LED.
ZONE NO.
TRIGGER TYPE
INPUT DESCRIPTION
1
Multiplexed Input
BLUE (H1/6)
2
Multiplexed Shock Sensor Input Mux BLUE wire.
3
Door Trigger
GREEN (H1/5) and VIOLET (H1/7).
4
Multiplexed Shock Sensor
Mux GREEN wire
5
Ignition
Yellow ribbon harness wire
6
Hood Brake Trigger
GRAY on the 5-pin shutdown harness.
Summary of Contents for Ungo Pro Security SR1000
Page 2: ......
Page 53: ...wiring quick reference guide ...
Page 54: ...relay satellite wiring quick reference guide ...