45
3-5 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 SECONDS:
If the unit is programmed for
no engine checking or voltage sense, the crank time must be set to the appropriate duration. The
default setting is 0.6 second. If a different crank time is desired, select feature 3-5 and select either
0.6 second by using the one-chirp setting or toggle through the higher settings by using the two-chirp
settings.
3-6 VOLTAGE CHECK HI/LOW:
This feature only functions when programmed for voltage sense.
Some vehicles have many accessories, which are turned on when remote started. In these vehicles,
the variation of voltage between the engine off and the car running is very small and the remote start
unit may "think" the vehicle has not started. This can cause the remote start to shut-down after the
car has been started. If this happens program this feature to the LOW position.
3-7 SHORT RUN/TURBO:
When the
and
buttons on the remote are pressed simultane-
ously, the vehicle will start for the programmed short run time. The factory default is 1 minute.
3-8 ACTIVATION PULSE COUNT:
This allows the system to use 1 or 2 pulses to activate the remote
start sequence.
N
Noottee!! 1 or 2 pulses on the WHITE/BLUE remote start activation input wire as well as the
button of the
remote control.
3-9 2nd IGNITION/2nd ACCESSORY OUTPUT:
This will allow the PINK/WHITE to be used as a 2nd
ignition or an accessory.
3-10 ACCESSORY STATE DURING WAIT-TO-START:
This feature will allow the selection of the acces-
sory output to be ON or OFF during wait-to-start.
3-11 2nd STATUS OUTPUT:
This feature will allow selection of status output or a rear defogger mode
that turns on ten seconds after the vehicle has started. The defogger mode has two selections, latched
or pulsed. Latched mode will only stay on for 10 minutes.
3-12 ANTI-GRIND ON/OFF:
With the anti-grind On (default) the ground-when-armed output will
be active during remote start operation. If accessories such as a voice module or window module
are added to the unit, it may be necessary to program this feature off.
Summary of Contents for Ungo Pro Security SR1000
Page 2: ......
Page 53: ...wiring quick reference guide ...
Page 54: ...relay satellite wiring quick reference guide ...