43
a trigger on that zone again, the system resets the one hour timer. If one hour passes and the zone
has not triggered again, the zone is activated and can trigger the system again. The false alarm pre-
vention circuitry only monitors sensor inputs, and does not bypass the door trigger or the ignition
trigger at any time. If the false alarm prevention circuitry is turned off, the system will respond to
repeated triggers on the sensor inputs and will do so indefinitely. Some states have laws regulating
how many times a security system can trigger before it is considered a nuisance and the vehicle is
towed away.
2-4 PROGRESSIVE DOOR TRIGGER ON/OFF:
The system responds to a door trigger input with a
progressive response. When the door is opened with the system armed, the siren will chirp 10 times
prior to the full triggered sequence. The door trigger is still treated as an instant trigger and closing
the door quickly will not prevent full triggered sequence from occurring. If the progressive door trig-
ger is programmed off, the full siren output will occur the moment the door is opened.
2-5 OVERRIDE PULSE COUNT 1 TO 5 PULSES:
The system can be programmed to count the num-
ber of presses of the override switch before disarming the security system. The factory default setting
is one pulse. The unit can also be set for two to five pulses.
Hidden Switch option: For added security, the GRAY wire on the two-pin override plug can be connected to any
switch in the vehicle that provides a positive (+) momentary pulse.
2-6 DOOR SENSOR BYPASS CHIRP ON/OFF:
This feature controls the error chirp that is generated
if the system is armed with the door trigger active. This is useful in vehicles that have a long dome
light delay after the door has been closed. If the system is armed before the dome light has turned
off, the security system will generate the door trigger error chirp. If this error chirp is not desired, use
this feature to disable the door open error chirp. If the bypass chirp is turned off, no bypass chirp
will be generated, even if a door is accidentally left open.
2-7 IGNITION CONTROLLED DOME LIGHT SUPERVISION ON/OFF:
If turned on, the system will turn
on the dome light for 60 seconds when the ignition is turned off. The optional dome light supervi-
sion feature must be installed as described in the Wire Connection Guide.
2-8 DOUBLE PULSE UNLOCK ON/OFF:
Some vehicles require two pulses on a single wire to unlock
the doors. When the double pulse unlock feature is turned on, the BLUE wire will supply two nega-
tive pulses instead of a single pulse. At the same time, the GREEN wire will supply two positive puls-
es instead of a single pulse. This makes it possible to directly interface with double pulse vehicles
without any extra parts.
2-9 FACTORY ALARM DISARM WITH CHANNEL 2:
In the default setting the factory alarm disarm
output will disarm the factory alarm system any time the button(s) controlling Channel Two is pressed.
2-10 CHANNEL 4 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/90
Summary of Contents for Ungo Pro Security SR1000
Page 2: ......
Page 53: ...wiring quick reference guide ...
Page 54: ...relay satellite wiring quick reference guide ...