Chapter 3 General Configuration and Monitoring
46
78-4025112-01 Rev H0
5
In the Multicast Join ports field, configure if the IGMP Joins for multicast streams
is to be sent on Singe/Both ports. This field is applicable only when the detection
mode is set to “Ethernet Link & UDP/L2TPv3 Packets & TS Socket”.
6
In the
LOS Timeout
field, configure the failover time from the active to inactive
port.
7
In the
Revert to Primary
field, if automatic revert is desired, set the parameter to
"Enabled". This field will not be applicable when the detection mode is set to
"Ethernet Link & UDP/L2TPv3 Packets & TS Socket" and will be set to Disabled.
8
In the
Revert Check Time
field, enter an uptime range for the primary port before a
reversion occurs.
Note:
Valid range is 0-300 seconds.
9
Click
Apply
.
10
Click
Save
.
Configuring Reversion of Multicast Streams to Primary Port
1
Navigate to the System/Input Redundancy Revert page.
Result
: The Input Redundancy Revert page is displayed.
2
Check or Uncheck the Schedule Revert To Primary Gbe Port to Enable/Disable
the automatic reversion.
3
Select the Reversion type as either one of the below.
-
Revert on These Days
-
Revert Every "X"hours.
4
If Selecting the "Revert on These Days", configure the days and time of the day
when the reversion is to occur.
Summary of Contents for RF Gateway 1 Modules
Page 1: ...78 4025112 01 R ev H0 Cisco RF Gateway 1 Configuration Guide ...
Page 2: ......
Page 10: ...Contents viii 78 4025112 01 Rev H0 Electrical GbE SFP Transceiver 254 Glossary 255 Index 259 ...
Page 20: ...Important Safety Instructions xviii 78 4025112 01 Rev H0 ...
Page 24: ......
Page 26: ......
Page 48: ......
Page 128: ......
Page 150: ......
Page 170: ......
Page 174: ......
Page 178: ......
Page 192: ......
Page 248: ......
Page 260: ......
Page 272: ......
Page 282: ......