![background image](http://html.mh-extra.com/html/cisco/rf-gateway-1-modules/rf-gateway-1-modules_configuration-manual_64976080.webp)
Chapter 3 General Configuration and Monitoring
56
78-4025112-01 Rev H0
Status
Describes stream status.
Stream active stream is bound to a video source and is active.
Input Loss: Stream mapped but no video
Wait for PAT: Stream mapped but waiting for PAT.
Wait for PMT: Stream mapped but waiting for PMT.
Content Loss: Stream content loss detected.
Bad Input: Input stream issues found too many SI changes.
Wait on Content: Stream content arrival pending.
Input PID Conflict: Input Stream contains PID conflict.
Input Program Number
Program number of input stream.
Input PMT PID
PID of the stream's PMT.
Input PCR PID
PID of the stream's PCR.
Total Elementary Stream
PIDs
Number of input PIDs. Varies with SPTS and MPTS.
Input Bitrate
Bitrate of the input program stream.
For MPTS streams, the Details button (the first button under the
Program Number
parameter) provides additional information on Elementary Streams. The following
screen appears.
Device Information
The following platform related device information is available for the RF Gateway 1.
Temperature
Power Supply voltage
Fan tachometer reading
Resource Utilization (V2.1.9)
The current status of the above components are monitored and if normal thresholds
of operation are exceeded, an alarm will generate on the system. Refer to
Fault
Management of the RF Gateway 1
(on page 65) for additional information.
Summary of Contents for RF Gateway 1 Modules
Page 1: ...78 4025112 01 R ev H0 Cisco RF Gateway 1 Configuration Guide ...
Page 2: ......
Page 10: ...Contents viii 78 4025112 01 Rev H0 Electrical GbE SFP Transceiver 254 Glossary 255 Index 259 ...
Page 20: ...Important Safety Instructions xviii 78 4025112 01 Rev H0 ...
Page 24: ......
Page 26: ......
Page 48: ......
Page 128: ......
Page 150: ......
Page 170: ......
Page 174: ......
Page 178: ......
Page 192: ......
Page 248: ......
Page 260: ......
Page 272: ......
Page 282: ......