Chapter 13 Encryption and Scrambling
190
78-4025112-01 Rev H0
Result:
The following page is displayed.
4
Click
Connection
.
Result:
The
Connection
table is displayed.
5
Click
Add New Connection
.
Result:
A new row is added to the
Connection
table.
6
In the
Priority
box of this entry, enter a channel priority number to determine the
ECMG working mode.
7
In the
IP Address
box, enter the IP address of the ECMG. The octets of the IP
address must be separated by dots.
8
In the
Port
box, enter the port number of the ECMG used for this channel.
9
In the
ECMG Port Selection
box,
enter the Ethernet port to use for
communication with the ECMG.