Chapter 13 Encryption and Scrambling
192
78-4025112-01 Rev H0
Overrule AC Stop Delay (ms)
The amount of time between the end of the last cryptoperiod
preceding a change in Access Criteria and the end of broadcasting
the ECM attached to this period.
Overrule Repetition Period (ms) The amount of time between two ECM packets at the output of the
scrambler.
Overrule Max. Streams:
The maximum number of simultaneous open streams supported by
an ECMG on a channel. If the ECMG returns 0, no maximum is
known. The scrambler will not limit the amount of streams on a
channel and no ECMs will be requested from the ECMG backup
when maximum capacity is reached on the ECMG. To make sure an
ECMG is not overloaded, the maximum number of streams can be
overruled.
Overrule Hint Bit Start Delay
(ms)
[Visible only for the Internal PowerKEY ECMG]
The amount of time before the start of the new cryptoperiod from
which the Hint Bit should be set in the PowerKEY ECM’s.
Overrule Hint Bit Stop Delay
(ms)
[Visible only for the Internal PowerKEY ECMG]
The amount of time before the start of the new cryptoperiod from
which the Hint Bit should be cleared in the PowerKEY ECM’s.
The following table shows the minimum, maximum, and default values of these
parameters.
Parameter
Minimum Value Maximum Value Default Value
Overrule Max Comp Time (ms)
0
60,000
5,000
Overrule Min CP Duration (ms)
1,000
3,600,000
10,000
Overrule Transition Start Delay (ms) -30,000
0
-2,000
Overrule Transition Stop Delay (ms) 0
30,000
2,000
Overrule Start Delay (ms)
-30,000
30,000
-2,000
Overrule Stop Delay (ms)
-30,000
30,000
-2,000
Overrule AC Start Delay (ms)
-30,000
30,000
-2,000
Overrule AC Stop Delay (ms)
-30,000
30,000
-2,100
Overrule Repetition Period (ms)
0
30,000
100
Overrule Max. Streams
0
30,000
512
Independent of the active/inactive state of a RFGW-1 participating in a CA
application, the RFGW-1 will be connected to the ECMG by default.
Changing Channel Status Message Parameter Values
Follow the instructions below to change message parameter values.
1
Click
Advanced
.
Summary of Contents for RF Gateway 1 Modules
Page 1: ...78 4025112 01 R ev H0 Cisco RF Gateway 1 Configuration Guide ...
Page 2: ......
Page 10: ...Contents viii 78 4025112 01 Rev H0 Electrical GbE SFP Transceiver 254 Glossary 255 Index 259 ...
Page 20: ...Important Safety Instructions xviii 78 4025112 01 Rev H0 ...
Page 24: ......
Page 26: ......
Page 48: ......
Page 128: ......
Page 150: ......
Page 170: ......
Page 174: ......
Page 178: ......
Page 192: ......
Page 248: ......
Page 260: ......
Page 272: ......
Page 282: ......