background image

 

 

Installation and Administration 

NetLink Open Applications Interface (OAI) Gateway 

Part Number: 72-0078-07 

Issue B 

 

Summary of Contents for MOG600

Page 1: ...Installation and Administration NetLink Open Applications Interface OAI Gateway Part Number 72 0078 07 Issue B ...

Page 2: ... consequential damages whatsoever including but not limited to lost profits arising out of or related to this document or the information contained in it even if SpectraLink has been advised knew or should have known of the possibility of such damages Trademark Information SpectraLink The SpectraLink logo LinkPlus Link NetLink SVP Are trademarks and registered trademarks of SpectraLink Corporation...

Page 3: ...e must accept any interference received including interference that may cause undesired operation TUV Rheinland of North America is a Nationally Recognized Testing Laboratory NRTL in the United States and is accredited by the Standards Council of Canada to test and certify products to Canadian National Standards Clients can demonstrate compliance for both U S and Canadian markets through a single ...

Page 4: ...um REN for your calling area If your telephone equipment causes harm to the telephone network the telephone service may discontinue your service temporarily If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be informed of your right to file a complaint with the FCC Your telephone company may make changes in its facil...

Page 5: ...the supplier Any repairs or alterations made by a user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaut...

Page 6: ...y to Application Server via the LAN 14 3 6 Connect the NetLink OAI Gateway to Application Server via a modem 14 4 The Main Menu 15 4 1 NetLink OAI System Main Menu 15 4 2 IP Systems Main Menu 16 5 Configuration Procedures 17 5 1 OAI Box Configuration 18 5 2 Network Configuration 19 5 3 OAI Line Configuration 21 5 4 Telephone Line Configuration 22 5 5 Deleting a Handset 23 5 6 Searching for a Hands...

Page 7: ...nk Telephony Gateway Installation Configuration and Administration 72 0065 02 Available at http www spectralink com consumer resources manuals jsp NetLink Wireless Telephone Configuration and Administration 72 1065 09 Available at http www spectralink com consumer resources manuals jsp 1 2 Customer Support Hotline SpectraLink wants you to have a successful installation If you have questions please...

Page 8: ...OG720 256 MOG730 512 MOG740 1 024 MOG750 10 000 As shown in the diagram below a single NetLink OAI Gateway is connected to the site s Local Area Network LAN via an Ethernet switch The connection to the OAI Application Server can be accomplished by a direct connect RS 232 or through the Ethernet connection but may run only via one connection at a time During setup the IP address of the NetLink OAI ...

Page 9: ...int Wireless Data Device Wireless Telephones Access Point Wired Telephones Direct Connect 3 rd Party Applications Paging Controller Nurse Call Systems Industrial Controllers See Application Note for Specific Installation Server for 3 rd Party OAI Application NetLink OAI Gateway LAN Backbone LAN based 3rd Party Applications Email Server LAN Clients Internet Wired telephone system OAI protocol RS 23...

Page 10: ...work collisions E rror LED Lit when the system has detected an error Status LEDs indicate system messages and status 1 Heartbeat indicates NetLink OAI Gateway is running 2 3 and 4 Currently unused 5 System master L N K O K A C T C O L E R R O R 3 4 5 1 2 STATUS NETWORK RS 232 port Model MOG7xx Offered in scaled increments to support up to 10 000 users RS 232 port L A C 3 4 5 E 1 2 NET Model MOG6xx...

Page 11: ...w system installation place power up and test the OAI Gateway when the rest of the system is tested See the Setup and Maintenance NetLink Wireless Telephone document for your system for more information Installing in an Existing System If you are adding OAI to an existing system the entire system will need to be reset before the NetLink OAI Gateway can be used See the Setup and Maintenance NetLink...

Page 12: ...ntil you see the Login prompt 5 At the Login prompt enter the default login admin and default password admin These are case sensitive 6 You can now configure the NetLink OAI Gateway including IP address following the procedure explained in the next section Changing the IP Address When utilizing the serial port as the primary communication link with the application server the OAI command described ...

Page 13: ...AI Gateway If your applications have the ability to communicate OAI messages over TCP IP and do not require a serial connection the RS 232 cabling is not required and you may use the LAN connection port 5456 via the Ethernet switch for your applications Connect the application server to the Gateway s serial port using a cable that conforms to RS 232 standards for DTE to DTE connections sometimes c...

Page 14: ...r the NetLink OAI Gateway to function on the LAN Follow the application s instructions to identify the Gateway to the application OAI Gateway Application Server PC LAN Ethernet switch 3 6 Connect the NetLink OAI Gateway to Application Server via a modem In some situations a modem is used for remote administration of the NetLink OAI Gateway Connect the modem to the Gateway s serial port using a cab...

Page 15: ...plays 4 1 NetLink OAI System Main Menu TFTP Server Download Configuration This is the default main menu of the OAI Administration console This menu may change when the configuration procedure is completed depending on the OAI Gateway and the type of system See following page for the IP systems main menu Note that if the OAI Gateway is a MOG6xx model the TFTP Server Download Configuration option ap...

Page 16: ...k OAI Gateway 4 2 IP Systems Main Menu One the configuration procedure is completed the IP System menu adds a Feature Programming option Additionally the OAI Line Configuration option is replaced by a Telephone Line Configuration option PN 72 0078 07 B doc Page 16 ...

Page 17: ...ese configuration procedures should be done after the handsets have been configured in the NetLink Telephony Gateway Generally configuration follows these steps 1 Establish type of system through OAI Box Configuration option 2 Establish Network settings through Network Configuration option 3 Configure the handsets through either OAI Line Configuration for NetLink Gateway systems or through Telepho...

Page 18: ...ith mogX00 If you are using NetLink Telephony Gateway s in your system change this option to Yes Note mogX00 is a model designation for the OAI Gateway TFTP Download Master Enter the IP address of the TFTP server Maintenance Lock The system sets this option to Yes when the system needs to be reset Note that the administrator cannot change this option It is automatically set by the system after cer...

Page 19: ... information Ethernet Address This is the MAC address of the gateway set at the factory and not user configurable IP Address Established in the initial serial connection and may be changed as needed The IP address of the NetLink OAI Gateway defined by your network administrator Enter the complete address including digits and periods DHCP should not be used with IP OAI Hostname Change the default h...

Page 20: ...e hostnames to IP addresses When using Telnet it is also possible to access the OAI Gateway using its hostname instead of the IP address Logging and Log server Logging can be set to Syslog or NONE The log server is the IP address or hostname of the syslog server on the network The gateway will output syslog format diagnostic messages This is usually not needed SNTP server Can be set to a hostname ...

Page 21: ...Link OAI System menu select OAI Line Configuration A screen similar to the following displays Enter the Hostname of the NetLink Telephony Gateway The OAI Gateway will fill in the hostname and port number based on the last entry Simply press Enter to accept the default port number and Hostname as you continue to the next line If the Telephony Gateway is active on the network the IP address field wi...

Page 22: ...er underneath the battery on the handset It can also be displayed on the handset by turning off the handset and then pressing and holding the Pwr power button The MAC address appears on the first line of the display 12 characters The MAC address must be manually entered by typing the entire address including digits and colons Name Enter the user name assigned to the telephone This is for record ke...

Page 23: ...box 3 Type an appropriate search string and then press Enter 4 The success or failure of the search will be displayed at the bottom of the screen 5 The user can either continue to change the search string for different search criteria or escape by pressing the Esc key out of the search screen The first line of the Telephone Line Configuration or Telephone Line Status screen will then display the l...

Page 24: ...following displays Use the arrow keys to select the function number to associate with OAI and type any label up to six characters What you type here will be displayed on the handset menu In the example screen above the FCN key sequence will display PhonBk on the handset function menu The OAI application in this case is a phone book enabling speed dialing to those listed PN 72 0078 07 B doc Page 24...

Page 25: ... the NetLink OAI and Telephony Gateways all have the same password To set or change the password select the Change Password option from the NetLink OAI System menu This option is on NetLink Telephony Gateway systems only It allows you to set the password established here on all NetLink Gateways in the system Using this option overrides any password already established on the NetLink Telephony Gate...

Page 26: ...l be Yes when the application is communicating correctly with the NetLink OAI Gateway It will be No when the application is not connected This will change dynamically Error Status The only OAI specific error is No ECP heartbeat which means the application failed to send a heartbeat to the Gateway Network Status Information about the connection to the Local Area Network LAN Software Versions Lists ...

Page 27: ... statistics have been accumulating in the Pkts and Bytes columns This is either the system uptime or the time since a user pressed C Clear while viewing this display User Time Period The length of time in seconds statistics will accumulate in the Userpkts column before resetting to zero When troubleshooting a problem use this setting to isolate statistics for a given time period for example one ho...

Page 28: ...ber of times the Ethernet controller has signaled the microprocessor that it has received or sent a packet Collisions The number of times the Ethernet controller has attempted to send a packet but another device on the network transmitted at the same time corrupting the transmission Collision Drops The number of packets the Ethernet controller has discarded because there were over sixteen collisio...

Page 29: ...ayed here Move to the next group of 16 by using the arrow keys WT MAC The MAC address of the handset entered at configuration Name Extension These fields contain the data entered at configuration Phone No ChkIn indicates the handset is not currently using the OAI function ChkIn indicates the handset is currently communicating with the Gateway The functioning of the S Search hotkey is described und...

Page 30: ...on will help you determine if you are running the most recent version and will assist SpectraLink engineering and or customer support in troubleshooting software problems There are two separate methods of downloading new software one for the IP system and one for the NetLink Telephony Gateway system See section 9 Software Maintenance for information about upgrading or downloading your software Fro...

Page 31: ...nstallation continue with handset registration and PBX programming and perform the usual voice and coverage tests when handset installation is complete If you added the NetLink OAI Gateway to an existing system place a call and test the features on each handset to be sure the system is working properly Test the application on each handset Consult your application provider for specific test procedu...

Page 32: ...ode used by the corresponding component The FTP File Transfer Protocol method of transfer is used In the NetLink OAI Gateway the flash file system has the following files File name Description config bin The OAI box configuraton fnctla bin The functional code oaiptlst bin The phone list configuration oaipttlsb bin The redundant phone list configuration The fnctla bin file is upgraded periodically ...

Page 33: ... login admin and password default is admin A login confirmation message will display followed by the FTP prompt 3 At the FTP prompt type binary A confirmation message will display 4 At the FTP prompt use the put command to transfer the functional code file to the client server or OAI Gateway It must be renamed before being loaded into the OAI Gateway The download file is named MOG700 bin Rename it...

Page 34: ... obtain the software for example downloading from a Web site Obtain and load a TFTP server on a LAN connected system Consult your server vendor s documentation for information about TFTP Once the update is obtained from SpectraLink load it in a location that is accessible by the TFTP program To configure the host and start the download select the TFTP Server Download Configuration option from the ...

Page 35: ...ss Device Planning Worksheet Copy and complete this worksheet to track parameters for each NetLink Wireless Telephone OAI Port MAC Address User Name Dialing Ext IP Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 PN 72 0078 07 B doc Page 35 ...