16-105
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
April 2006
Chapter 16 Card Reference
16.8.5 MXP_2.5G_10E Card
16.8.5.13 Automatic Laser Shutdown
The ALS procedure is supported on both client and trunk interfaces. On the client interface, ALS is
compliant with ITU-T G.664 (6/99). On the data application and trunk interface, the switch on and off
pulse duration is greater than 60 seconds. The on and off pulse duration is user-configurable. For ALS
provisioning information, see the
“DLP-G223 Change Line Settings for MXP_2.5G_10G and
MXP_2.5G_10E Cards” section on page 5-34
16.8.5.14 Jitter
For SONET and SDH signals, the MXP_2.5G_10E card complies to GR-253-CORE, ITU-T G.825, and
ITU-T G.873 for jitter generation, jitter tolerance, and jitter transfer.
34.2
1535.82
34.2
1536.61
38.1
1538.19
38.1
1538.98
38.1
1539.77
38.1
1540.56
42.1
1542.14
42.1
1542.94
42.1
1543.73
42.1
1544.53
46.1
1546.12
46.1
1546.92
46.1
1547.72
46.1
1548.51
50.1
1550.12
50.1
1550.92
50.1
1551.72
50.1
1552.52
54.1
1554.13
54.1
1554.94
54.1
1555.75
54.1
1556.55
58.1
1558.17
58.1
1558.98
58.1
1559.79
58.1
1560.61
Table 16-60
MXP_2.5G_10E Trunk Wavelengths (continued)
Band
Wavelength (nm)
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...