![Cisco ONS 15454 DWDM Installation And Operation Manual Download Page 330](http://html.mh-extra.com/html/cisco/ons-15454-dwdm/ons-15454-dwdm_installation-and-operation-manual_63831330.webp)
4-50
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 4 Perform Node Acceptance Tests
DLP-G90 Verify an AD-xB-xx.x Pass-Through Connection Power
Step 14
(Optional) Perform one of the following:
•
If an OSCM card is installed, connect a power meter to LINE TX port on the card front panel and
verify that the east OPT-BST amplifier is turned on by the pass-through wavelength.
•
If an OSC-CSM card is installed, complete the
“DLP-G84 Verify the OSC-CSM Incoming Power”
for the east OSC-CSM card.
Step 15
Return to your originating procedure (NTP).
DLP-G90 Verify an AD-xB-xx.x Pass-Through Connection Power
Step 1
Verify the east AD-xB-xx.x band TX power:
a.
Display the east AD-xB-xx.x card in card view.
b.
Click the
Provisioning > Optical Band > Parameters
tabs.
c.
Change the Admin State of the BAND TX (east-to-west) port related to the wavelength selected on
the tunable laser to
OOS,MT
(ANSI) or
Locked,maintenance
(ETSI). Click
Apply
.
d.
Verify that the BAND TX port Power value is higher than the default no-power value of –30 dBm.
Step 2
Verify the west AD-xB-xx.x card RX and TX power:
a.
Display the west AD-xB-xx.x card in card view.
b.
Click the
Provisioning > Optical Band > Parameters
tabs.
c.
Verify that the Power value of the BAND RX (east-to-west) port is higher than the default no-power
value of –30 dBm.
d.
Change the Admin State of the BAND TX (west-to-east) port related to the wavelength selected on
the tunable laser to
OOS,MT
(ANSI) or
Locked,maintenance
(ETSI). Click
Apply
.
e.
Verify that the BAND TX port Power value is higher than the default no-power value of –30 dBm.
Step 3
Verify the band RX port on the east AD-xB-xx.x card:
a.
Display the east AD-xB-xx.x card in card view.
b.
Click the
Provisioning > Optical Band > Parameters
tabs.
c.
Verify that the Power value of the BAND RX (west-to-east) port is higher than the default no-power
value of –30 dBm.
Step 4
Return to your originating procedure (NTP).
Purpose
This task verifies an AD-xB-xx.x pass-through connection.
Tools/Equipment
None
Prerequisite Procedures
DLP-G46 Log into CTC, page 2-25
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...