![Cisco ONS 15454 DWDM Installation And Operation Manual Download Page 1051](http://html.mh-extra.com/html/cisco/ons-15454-dwdm/ons-15454-dwdm_installation-and-operation-manual_638311051.webp)
B-21
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
December 2006
Appendix B Hardware Specifications
B.4.10 AD-1C-xx.x Card Specifications
The 4MD-xx.x card has the following additional specifications:
•
Environmental
–
Operating temperature:
C-Temp: –5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–
Operating humidity: 5 to 95 percent RH
•
Dimensions
–
Height: 12.65 in. (321.3 mm)
–
Width: 0.92 in. (23.4 mm)
–
Depth: 9.00 in. (228.6 mm)
B.4.10 AD-1C-xx.x Card Specifications
lists the AD-1C-xx.x optical specifications.
Table B-7
4MD-xx.x Optical Specifications
Parameter
Note
Condition
Min
Max
Unit
Trx filter shape
(–0.5 dB bandwidth
TrxBW
2
)
All SOP and within
whole operating
temperature range
COM Rx—xx.xx Tx
COM Rx—yy.yy Tx
COM Rx—zz.zz Tx
COM Rx—kk.kk Tx
+/–180
—
pm
xx.xx Rx—COM Tx
yy.yy Rx—COM Tx
zz.zz Rx—COM Tx
kk.kk Rx—COM Tx
Insertion loss
demultiplexer
section
All SOP and within
whole operating
temperature range
COM Rx—xx.xx Tx —
1.9
dB
COM Rx—yy.yy Tx —
2.4
dB
COM Rx—zz.zz Tx
—
2.8
dB
COM Rx—kk.kk Tx —
3.3
dB
Insertion loss
multiplexer section
All SOP and within
whole operating
temperature range
(two connectors
included)
xx.xx Rx—COM Tx —
3.6
dB
yy.yy Rx—COM Tx —
3.2
dB
zz.zz Rx—COM Tx
—
3.0
dB
kk.kk Rx—COM Tx —
2.6
dB
VOA dynamic range —
—
25
—
dB
Maximum optical
input power
—
—
300
—
mW
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...