Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 4 Perform Node Acceptance Tests
DLP-G91 Verify an AD-xC-xx.x Pass-Through Connection
DLP-G91 Verify an AD-xC-xx.x Pass-Through Connection
Step 1
Verify the east AD-xC-xx.x channel TX power:
a.
Display the east AD-xC-xx.x card in card view.
b.
Click the
Provisioning > Optical Chn > Parameters
tabs.
c.
Verify that the power value for the CHAN TX port is higher than the default no-power value of
–35 dBm.
d.
If the AD-xC-xx.x card is an AD-4C-xx.x card, a VOA (applied to all four channels) is installed
along the drop path and needs to be activated in Step
e.
Change the Admin State of the CHAN TX port related to the wavelength selected on the tunable
laser to
OOS,MT
(ANSI) or
Locked,maintenance
(ETSI). Click
Apply
.
f.
Verify that the power value of the CHAN TX port is higher than the default no-power value of
–35 dBm.
Step 2
Verify the channel power for the corresponding west AD-xC-xx.x card:
a.
Display the west AD-xC-xx.x card in card view.
b.
Click the
Provisioning > Optical Chn > Parameters
tabs.
c.
Verify that the power value of the CHAN TX port is higher than the default no-power value of
–35 dBm.
d.
Verify that the Power value of the CHAN RX port reaches the provisioned setpoint (VOA Power
Ref).
e.
Change the Admin State of the CHAN TX port related to the wavelength selected on the tunable
laser to
OOS,MT
(ANSI) or
Locked,maintenance
(ETSI). Click
Apply
.
f.
If the AD-xC-xx.x is an AD-4C-W card, a VOA (applying to all four channels) is installed along the
drop path and needs to be activated in Step
g.
Change the Admin State of the CHAN TX port related to the wavelength selected on the tunable
laser to
OOS,MT
(ANSI) or
Locked,maintenance
(ETSI). Click
Apply
.
h.
Verify that the power value of the CHAN TX port is higher than the default no-power value of
–35 dBm.
Step 3
Verify the east AD-xC-xx.x channel RX power:
a.
Display the east AD-xC-xx.x card in card view.
b.
Click the
Provisioning > Optical Chn > Parameters
tabs.
c.
Change the Admin State of the CHAN RX port to
OOS,MT
(ANSI) or
Locked,maintenance
(ETSI)
for the channel related to the wavelength selected on the tunable laser.
Purpose
This task verifies an AD-xC-xx.x pass-through connection.
Tools/Equipment
None
Prerequisite Procedures
DLP-G46 Log into CTC, page 2-25
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser