![Cisco ONS 15454 DWDM Installation And Operation Manual Download Page 1073](http://html.mh-extra.com/html/cisco/ons-15454-dwdm/ons-15454-dwdm_installation-and-operation-manual_638311073.webp)
B-43
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
December 2006
Appendix B Hardware Specifications
B.5.4 MXP_MR_2.5G and MXPP_MR_2.5G Card Specifications
–
Receiver sensitivity –28 dBm, BER 1 * 10 exp – 12
–
Receiver overload is equal to or exceeds –8 dBm
–
Receiver maximum reflectance of –27 dB
•
Line (client side)
–
Bit rate: 1.06 Gbps to 2.125 Gbps per client
–
Code: Scrambled NRZ
–
Fiber: 1310-nm single-mode or 850-nm multimode
–
Maximum chromatic dispersion allowance: 1600 ps/nm
–
Loopback modes: Terminal and facility
–
Connectors: LC
–
Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957
•
Transmitter (client side)
–
Maximum transmitter output power: –1 dBm
–
Minimum transmitter output power: –6 dBm
–
Center wavelength: 1290 to 1330 nm
–
Nominal wavelength: 1310 nm
–
Transmitter: DFB laser
•
Receiver (client side)
–
Maximum receiver level: –1 dBm at BER 1 * 10 exp – 12
–
Minimum receiver level: –14 dBm at BER 1 * 10 exp – 12
–
Receiver: APD
–
Link loss budget: 8 dB minimum, at BER = 1 * 10 exp – 12
–
Receiver input wavelength range: 1290 to 1605 nm
•
Environmental
–
Operating temperature: –5 to +40 degrees Celsius (+23 to +104 degrees Fahrenheit)
–
Operating humidity: 5 to 85 percent, noncondensing
–
Power consumption (maximum): 60 W, 1.25 A at –48 V, 204 BTU/hr
19 dB
N/A
<10 exp – 12
N/A
– 9 to – 23 dBm +/– 5400 ps/nm
21 dB
N/A
<10 exp – 12
N/A
– 9 to – 30 dBm —
21 dB
N/A
<10 exp – 12
N/A
– 9 to – 29 dBm +/– 1800 ps/nm
21 dB
N/A
<10 exp – 12
N/A
– 9 to – 28 dBm +/– 5400 ps/nm
22 dB
N/A
<10 exp – 12
N/A
– 9 to – 30 dBm +/– 1800 ps/nm
23 dB
N/A
<10 exp – 12
N/A
– 9 to – 30 dBm +/– 5400 ps/nm
1.
Optical Signal-to-Noise ratio (OSNR) defined with 0.1 nm Resolution Bandwidth (RBW)
Table B-20
MXP_MR_2.5G/MXPP_MR_2.5G Receiver Trunk Side Specifications (continued)
OSNR
1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power
Sensitivity
Chromatic Dispersion
Tolerance
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...