![Cisco ONS 15454 DWDM Installation And Operation Manual Download Page 83](http://html.mh-extra.com/html/cisco/ons-15454-dwdm/ons-15454-dwdm_installation-and-operation-manual_63831083.webp)
1-3
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
August 2005
Chapter 1 Install the Shelf and Common Control Cards
Required Tools and Equipment (ANSI)
Required Tools and Equipment (ANSI)
You need the following tools and equipment to install and test the ONS 15454 ANSI shelf assembly.
Cisco-Supplied Materials (ANSI)
The following materials are required and are shipped with the ONS 15454 ANSI shelf (wrapped in
plastic). The number in parentheses gives the quantity of the item included in the package.
•
#12-24 x 3/4 pan-head Phillips mounting screws (48-1004-XX, 48-1007-XX) (8)
•
#12 -24 x 3/4 socket set screws (48-1003-XX) (2)
•
T-handle #12-24 hex tool for set screws (1)
•
ESD wrist strap with 1.8 m (6 ft) coil cable (1)
•
Tie wraps (10)
•
Pinned hex (Allen) key for front door (1)
•
Spacers (50-1193-XX) (4)
•
Spacer mounting brackets (2)
•
Sheet metal backplane cover (installed) (1)
•
External (bottom) brackets for the fan-tray air filter
•
Standoff kit (53-0795-XX):
–
Plastic fiber management guides (2)
–
Fan filter bracket screws (53-48-0003) (6)
User-Supplied Materials (ANSI)
The following materials and tools are required but are not supplied with the ONS 15454 ANSI:
•
One or more of the following equipment racks:
–
19-inch ANSI Standard (Telcordia GR-63-CORE) (482.6 mm) rack; total width 22 inches
(558.8 mm)
–
23-inch ANSI Standard (Telcordia GR-63-CORE) (584.2 mm) rack; total width 26 inches
(660.4 mm)
•
Fuse panel
•
Power cable (from fuse and alarm panel to assembly), #10AWG, copper conductors,
194 degrees Fahrenheit (90 degrees Celsius)
•
Ground cable #6AWG stranded
•
Alarm cable pairs for all alarm connections, #22 or #24 AWG (0.51 mm² or 0.64 mm²), solid tinned
•
100-ohm shielded BITS clock cable pair #22 or #24 AWG (0.51 mm² or 0.64 mm²), twisted-pair
T1-type
•
Single-mode SC fiber jumpers with UPC polish (55 dB or better) for optical (OC-N) cards
•
Shielded coaxial cable terminated with SMB or BNC connectors for DS-3 cards
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...