Line Card Installation
▀ Line Card Redundancy
▄ ASR 5000 Installation Guide
96
CLI Commands for XGLC Redundancy
Side-by-side 1:1 redundancy only operates on top line card slot numbers: cards 17 through 23 and 26 through 32. Make
sure that both packet processing cards in front of the line cards are of the same type, configured as a redundant pair, and
active.The CLI configuration to support this redundancy mode is specified at the card level as follows:
[local]asr5000#
config
[local]asr5000(config)#
card 17
[local]asr5000(config-card-17)#
redundant with 18
To remove this configuration, set the redundant card back to the default bottom line card:
[local]asr5000(config-card-17)#
redundant with 33